2-2-2
ERR LED Indicator
The Error LED (ERR) indicates the presence and type of an error within the Industrial Box PC.
Color
Status
Meaning
Red
Not lit
•
The 24 VDC power is not supplied
•
No error is present
Blinking
•
Fan Error
•
Battery low
Lit
•
Thermal shutdown
•
Watchdog Error
•
Power Supply undervoltage error
•
Power Supply overvoltage error
•
Power supply defective
Additional Information
• The status of this LED can also be defined by users using the Industrial PC System API.
Refer to
3-3-2 Industrial PC System API
on page 3 - 19 for Industrial PC System API details.
• Refer to
on page 7 - 13 for actions to solve errors.
2-2-3
HDD LED Indicator
The Hard Disk Drive LED (HDD) indicates activity of the HDD or SSD.
Color
Status
Meaning
Yellow
Flickering
The HDD or SSD is active.
2-2-4
RUN LED Indicator
The RUN LED is available for user applications.
Color
Status
Meaning
Green
Not lit
User-defined.
The status can be defined in a user program using the
Industrial PC System API.
Blinking
Lit
Additional Information
Refer to
3-3-2 Industrial PC System API
on page 3 - 19 for Industrial PC System API details.
2 Hardware
2 - 6
NY-series Industrial Box PC User's Manual (W553)
Summary of Contents for NYB17-11
Page 30: ...Sections in this Manual 28 NY series Industrial Box PC User s Manual W553...
Page 38: ...1 Overview 1 8 NY series Industrial Box PC User s Manual W553...
Page 60: ...2 Hardware 2 22 NY series Industrial Box PC User s Manual W553...
Page 218: ...7 Maintenance 7 42 NY series Industrial Box PC User s Manual W553...
Page 239: ...I Index I 1 NY series Industrial Box PC User s Manual W553 I...
Page 242: ......
Page 243: ......