background image

Terms and Conditions Agreement 

 
Read and understand this catalog. 
Please read and understand this catalog before purchasing the products.    Please consult your OMRON representative if you 
have any questions or comments.     
 
Warranties. 
(a) Exclusive Warranty

. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship 

for a period of twelve months  from the date of sale by Omron (or such other period expressed in  writing  by  Omron).  Omron 
disclaims all other warranties, express or implied. 
(b)  Limitations.  OMRON  MAKES  NO  WARRANTY  OR  REPRESENTATION,  EXPRESS  OR  IMPLIED,  ABOUT 
NON-INFRINGEMENT,  MERCHANTABILITY  OR FITNESS FOR A  PARTICULAR PURPOSE OF  THE  PRODUCTS. BUYER 
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE 
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. 
Omron  further  disclaims  all  warranties  and  responsibility  of  any  type  for  claims  or  expenses  based  on  infringement  by  the 
Products  or  otherwise  of  any  intellectual  property  right.  (c)  Buyer  Re

medy.  Omron’s  sole  obligation  hereunder  shall  be,  at 

Omron’s  election,  to  (i)  replace  (in  the  form  originally  shipped  with  Buyer  responsible  for  labor  charges  for  removal  or 
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount 
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, 
repair, indemnity or any other claims or expenses regarding the Products unless Omron

’s analysis confirms that the Products 

were  properly  handled,  stored,  installed  and  maintained  and  not  subject  to  contamination,  abuse,  misuse  or  inappropriate 
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall 
not  be  liable  for  the  suitability  or  unsuitability  or  the  results  from  the  use  of  Products  in  combination  with  any  electrical  or 
electronic  components,  circuits,  system  assemblies  or  any  other  materials  or  substances  or  environments.  Any  advice, 
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above 
warranty. 
See 

http://www.omron.com/global/

    or contact your Omron representative for published information. 

 
Limitation on Liability; Etc. 
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, 
LOSS  OF  PROFITS  OR  PRODUCTION  OR  COMMERCIAL  LOSS  IN  ANY  WAY  CONNECTED  WITH  THE  PRODUCTS, 
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. 
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 
 
Suitability of Use. 
Omron  Companies  shall  not  be  responsible  for  conformity  with  any  standards,  codes  or  regulations  which  apply  to  the 
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable 
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself 
is  not  sufficient  for  a  complete  determination  of  the  suitability  of  the  Product  in  combination  with  the  end  product,  machine, 
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product 
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.   
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE 
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE 
OVERALL EQUIPMENT OR SYSTEM. 
 
Programmable Products. 
Omron  Companies  shall  not  be  responsible  for  the  user’s  programming  of  a  programmable  Product,  or  any  consequence 
thereof. 
 
Performance Data. 
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining 
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate 
it to actual application requirements. Actual performance is subject to the Om

ron’s Warranty and Limitations of Liability. 

 
Change in Specifications. 
Product  specifications  and  accessories  may  be  changed  at  any  time  based  on  improvements  and  other  reasons.  It  is  our 
practice to change part numbers when published ratings or features are changed, or when significant construction changes are 
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers 
may be assigned to fix or establish key specifications for your application. 

Please consult with your Omron’s representative at 

any time to confirm actual specifications of purchased Product. 
 
Errors and Omissions. 
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is 

assumed for clerical, typographical or proofreading errors or omissions.

 

 

 

 

2020.11 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2020 All Right Reserved. 

Summary of Contents for NXR-ILM08C-EIT

Page 1: ...rnet cables Communication quality of EtherNet IP Records the total number of received FCS errors which allows checking communication quality Communication quality of IO Link Records the total number o...

Page 2: ...port Software for the Controller L Network Configurator C EtherNet IP adapter NXR series EtherNet IP IO Link Master Unit F IO Link device NXR series IO Link I O Hub G Non IO Link connected External De...

Page 3: ...ted external device is a sensor actuator or other device that handles ON OFF signals that are not supported by IO Link H Ethernet switch This is a relay device that connects multiple nodes I Communica...

Page 4: ...chine Automation Controller System Controller CJ series NJ NX series Software FA Integrated Tool Package CX One Automation Software Sysmac Studio Product name Specifications Model Number of licenses M...

Page 5: ...HARTING K K M12 plug D coding male to M12 plug D coding male 4 Screw connector Straight straight 0 5 m 72MDm4MDm4005K 1 m 72MDm4MDm4010K 2 m 72MDm4MDm4020K 3 m 72MDm4MDm4030K 5 m 72MDm4MDm4050K 10 m...

Page 6: ...d appearance Manufacturer Specification No of cable conductors Connector Cable connection direction Cable length Model XS3W Socket and Plug on Cable Ends M8 Socket M12 Plug OMRON M8 socket A coding fe...

Page 7: ...85 with no condensation Altitude 2 000 m max Pollution degree 3 or less Conforms to IEC 61010 2 201 Noise immunity 2 kV on power supply line Conforms to IEC 61000 4 4 Overvoltage category Category II...

Page 8: ...distance 100 m or less Distance between nodes and between hub and node Topology Line Star Tree Ring Number of connected Units Line Star No restrictions Tree There is no restrictions in the number of...

Page 9: ...ations connectors and I O connectors M12 screw 0 5 to 0 6 N m Power supply connectors 7 8 inch screw 1 5 to 1 7 N m Unit mounting M5 screw 1 47 to 1 96 N m Rotary switch cover M3 screw 0 4 to 0 6 N m...

Page 10: ...mum load current 2 A pin Leakage current 0 1 mA max Residual voltage 1 5 V max ON OFF response time 1 0 ms max Short circuit protection Provided 3 Short circuit detection Provided 3 Current consumptio...

Page 11: ...twork Configurator CX ConfiguratorFDT NXR ILM08C EIT Ver 1 1 Ver 1 14 Ver 2 1 Ver 1 40 Ver 3 69 Ver 2 54 Ver 1 0 IO Link Master Unit Corresponding versions Model Unit version CPU unit version CS1W EIP...

Page 12: ...supply E Power supply connector output The connector for supplying Unit input power and output power from the local node to another node Use this connector when the power supply method is power supply...

Page 13: ...NXR ILM08C EIT 13 Dimensions Unit mm 16 5 6 5 5 5 Two M5 or 5 3 dia holes Mounting dimensions 14 2 24 2 37 26 8 19 2 38 47 5 14 5 17 45 62 26 7 97 7 122 7 147 7 172 7 208 7 240 19 2 32 8 45 5 227 0 2...

Page 14: ...mple for an IO Link device with digital outputs for pin 2 is shown below In this example the port is used in the following communications modes Pin 4 IO Link Mode pin 2 SIO DI Mode Power supply connec...

Page 15: ...and outputs for pin 2 is shown below In this example the port is used in the following communications modes Pin 4 IO Link Mode pin 2 Disabled 4 2 3 1 2 1 3 4 2 1 3 4 U IN P U IN P Power supply connect...

Page 16: ...Sensors In this example the port is used in the following communications modes Pin 4 SIO DI Mode pin 2 Disabled Three wire sensor PNP type 4 2 3 1 2 1 3 4 U IN P U IN P Power supply connector input I...

Page 17: ...k output device is shown below In this example the port is used in the following communications modes Pin 4 SIO DO Mode pin 2 Disabled 4 2 3 1 2 1 3 4 U IN P Non IO Link output device U IN P OUT P OUT...

Page 18: ...Master Unit The power supply connector output is not used This method does not cause voltage drop in through wiring cables or due to connection through IO Link Master Units Unit input power supply Ou...

Page 19: ...he power supply connector input of another IO Link Master Unit with a power supply cable In this way supply power with through wiring between the subsequent Units with power supply cables The power su...

Page 20: ...NS communications Sysmac Studio Version 1 Operation Manual W504 SYSMAC SE2 Learning about the operating procedures and functions of the Sysmac Studio Describes the operating procedures of the Sysmac S...

Page 21: ...her in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: