Summary of Contents for Zignature Pad-1410

Page 1: ...Quick Start Guide 1 ...

Page 2: ...Quick Start Guide 2 ...

Page 3: ...s 5 Software requirements 5 What s in the box 6 The Zignature Pad 7 Setup the Zignature Pad 8 Installing the Software Suite 9 Printing a document 11 How to use the Digital Pen 12 Uninstalling the Software Suite 12 Troubleshooting 13 User Safety Summary 16 Copyright 2008 2011 10ZiG Technology ...

Page 4: ...ontract and pen to the customer for signing If a document would normally be printed to a paper printer to have a document signed by a customer it can be printed to the Zignature Pad as an electronic document that captures electronic signatures The device uses advanced security and encryption techniques to store all modifications to the document with time stamps in a tamper evident environment Key ...

Page 5: ... For single setup Windows XP SP3 Vista with SP1 or Windows 7 32 or 64 bit operating system Net Framework v 2 0 preinstalled in Windows 7 Administrative privileges for installation For Citrix server setup Windows 2003 server or Windows 2008 server 32 or 64 bit with Citrix presentation server v 4 0 or above or XenApp v 5 0 or above For Citrix client setup A PC or 10ZiG thin client with Windows XP 3 ...

Page 6: ...s from the box to help you set up your Zignature Pad tablet Power Adapter USB Cable Product CD Electronic Pen Quick Start Guide Zignature Pad Use only the included AC adapter or one approved for this tablet If any of these items are missing from your packaging contact your reseller ...

Page 7: ...tart Guide 7 The Zignature Pad Back view Item Remark 1 DC In port 12VDC 2 USB B port Right view Item Remark 1 USB A port Optional 2 Smart Card reader Optional Front view Item Remark 1 Pen sensors 1 1 2 2 1 2 3 ...

Page 8: ...d USB A to the rear USB port on the host computer 3 Plug the cable attached to the AC adapter into the DC In port on the rear side 4 Plug the other end of the power adaptor into an AC outlet 5 The hardware is ready and the Zignature Pad should turn on and display the default logo 10ZiG logo NOTE Do not connect the USB adapter to the computer until software installation is complete 240V 60Hz Warnin...

Page 9: ...tart automatically If not run the program by selecting Run from the Windows Start menu and type in D setup exe If your CD drive uses a different letter type that letter instead of D Select your installation type single or Citrix server from list of options and follow the steps within the wizard to complete the setup If the current user has no administrative privileges the setup will ask to enter a...

Page 10: ...change it if necessary click Install The Installing screen shows the installation progress Define VPilot Server IP address dialog prompts you to enter IP address and port of your VPilot server see VPilot installation If you don t know yet the IP address you can define it later click Define later button The VPilot Server is not normally used for small installations ...

Page 11: ...lders is selected to provide read write file access for all users Clicks save to complete the installation If you keep the Start 10ZiG VPort check box checked on the last setup screen the software will start automatically and create connection to Zignature Pad The VPort Agent icon in the System Tray shows current connection status Right click the icon and select Configure Select Quick Print Docume...

Page 12: ...ries 1 Remove the battery compartment cover 2 Install two SR41 batteries with the positive facing up 3 Replace battery compartment cover Write Correctly When you pick up the pen find a position that is comfortable for you Be careful to hold the pen in a way that does not block the signals sent from the tip of the pen to the sensors receivers When writing make sure to apply enough pressure to activ...

Page 13: ... appears click Yes 6 When the Uninstall Complete window appears click OK 7 Restart your computer Troubleshooting If you run the setup again and you get warning 10ZiG Zignature Pad setup AddMonitor failed Error 3006 The specified print monitor has already been installed Continue and complete the installation uncheck Run 10ZiG VPort check box on the last screen and re run the setup ...

Page 14: ...unded ask an electrician to check the outlet Do not use an extension cord Warning Do not place the Zignature Pad where people may step on the power line or USB cable Do not place objects on the Zignature Pad or the power adaptor The following are hazards to your safety The power adaptor is damaged or frayed Liquid is spilled into the Zignature Pad The Zignature Pad is exposed to water Any part of ...

Page 15: ...Do not disassemble the device Operational Safety Do not place the Zignature Pad near a heat source Do not place the Zignature Pad in direct sunlight Place the Zignature Pad on a level solid surface with adequate strength for the weight of the device Do not place any liquids on or near the Zignature Pad ...