NXR-ILM08C-EIT
7
General Specifications
*1.
Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each
model.
Item
Specification
Degree of protection
IP67
Operating
environment
Ambient operating temperature
-10 to 55°C
Ambient operating humidity
25% to 85% (with no condensation)
Ambient operating atmosphere
Must be free from corrosive gases.
Storage temperature
-25 to 65°C
Storage humidity
25% to 85% (with no condensation)
Altitude
2,000 m max.
Pollution degree
3 or less: Conforms to IEC 61010-2-201.
Noise immunity
2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage category
Category II: Conforms to IEC 61010-2-201.
EMC immunity level
Zone B
Vibration resistance
10 to 60 Hz with amplitude of 0.35 mm, 60 to 150 Hz and 50 m/s
2
for 80 minutes each in X, Y, and Z directions.
Shock resistance
150 m/s
2
, 3 times each in 6 directions along X, Y, and Z axes
Dielectric strength
600 VAC (between isolated circuits)
Insulation resistance
20 M
Ω
min. (between isolated circuits)
Applicable standards
*
1
EU: EN 61131-2, RCM, KC, IO-Link conformance, EtherNet/IP conformance