![background image](http://html1.mh-extra.com/html/omron/nsa/nsa_manual_743135030.webp)
1-2 Specifications
1-2-2 General Specifications
1-6
1
O
v
er
view and Specif
icat
ions
Note 1-2: PCI Board Other Than a CLK Board or a CS1 Board Installed
The internal temperature of the PCI Board will rise 10
°
C at slot 1 and 15
°
C at slot 2. This may
place the ambient operating temperature at the high end of the range given in *1-1 above.
Therefore, set the ambient operating temperature according to the ambient operating
temperature of the PCI Board that is installed. Check prior to actual use to make sure the PCI
Board will operate properly at the selected ambient operating temperature.
Example: If a PCI Board with an ambient operating temperature of 0 to 45
°
C will be installed in
slot 1 with the Unit installed at angle greater than 45
°
and less than 75
°
off horizontal,
then the ambient operating temperature selected should be 0 to 35
°
C because of the
10
°
C rise in the internal temperature of the Board at slot 1.
0°
90°
Installation angle
LCD display side
Note 1-3: Ambient Operating Temperature
The ambient operating temperature is the temperature at a point 50 mm from the center of
the back of the Unit, and it includes the heat generated by the Unit itself.
50 mm
LCD
side
Back of the Unit
Ambient temperature
measuring point
Summary of Contents for NSA
Page 2: ......
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...xx...
Page 25: ...Section 1 Overview and Specifications...
Page 33: ...Section 2 Nomenclature...
Page 38: ...2 1 Nomenclature 2 1 3 Connectors and Interfaces 2 6 2 Nomenclature...
Page 39: ...Section 3 Installing the NSA series Industrial PC and Connecting Peripheral Devices...
Page 59: ...Section 4 RAS Functions...
Page 73: ...Section 5 Maintenance...
Page 81: ...Appendix...
Page 113: ......