![background image](http://html1.mh-extra.com/html/omron/nsa/nsa_manual_743135029.webp)
1-2 Specifications
1-2-2 General
Specifications
1-5
1
O
v
er
view and Specif
icat
ions
5:
The service life is a guideline that is provided strictly for reference. It varies with factors
such as the installation location and operating conditions.
6:
The file system is formatted in advance with NTFS. Both C and D drives have been
created as partitions. The D drive is used by the OS and RAS Utility to store the event
logs.
7:
NSA15-TX01B/S-01E only: 4 GB
8:
NSA15-TX01B/S-01E only: 1 GB
1-2-2 General Specifications
Item
Specifications
Rated supply voltage
24 V DC
Allowable supply voltage range
20.0 V DC to 27.6 V DC (24 V DC
±
15%)
Power consumption
NSA12: 80 W max., NSA15: 100 W max.
Ambient operating temperature
0 to 50
°
C (See notes 1 and 2.)
Ambient storage temperature
−
10 to 60
°
C (See note 2.)
Ambient operating humidity
10% to 80% with no condensation (See note 2.)
Ambient storage humidity
10% to 85% with no condensation (See note 2.)
Operating atmosphere
Must be free of corrosive gases.
Must be fairly dust free.
Noise resistance
Conforms to IEC6100-4-4, power supply line: 2 kV
Vibration resistance (in
operation)
Conforms to JIS C0041, 0.05-mm amplitude at 10 to 55 Hz for 50 min each
in the X, Y, and Z directions
Shock resistance (in operation)
Conforms to JIS C0041, 196 m/s
2
three times each in the X, Y, and Z
directions
Dimensions (excluding
protrusions)
NSA12: 322 mm x 264 mm x 100 mm (W x H x D)
NSA15: 384 mm x 312 mm x 108 mm (W x H x D)
Weight
NSA12: 5 kg max., NSA15: 7 kg max.
Degree of protection
Front panel: IP65 or the equivalent (display side only) (See note 3.)
Note 1: The maximum surrounding air temperature rating is 50
°
C. The ambient operating
temperature may be restricted as described below depending on whether a PCI Board
is installed, the type of Board installed, and the mounting angle of the Unit.
Note 1-1: No PCI Board or One of Following Expansion Boards Installed
•
3G8F7-CLK21-V1 Controller Link Board (hereafter CLK Board)
•
CS1PC-PCI01-DRM SYSMAC CS1 Board (hereafter CS1 Board)
(1) The ambient operating temperature is 0 to 25
°
C when the installation angle is greater than
0
°
and less than 15
°
off horizontal (excluding the memory card).
(2) The ambient operating temperature is 0 to 30
°
C when the installation angle is greater than
15
°
and less than 45
°
off horizontal (excluding the memory card).
(3) The ambient operating temperature is 0 to 40
°
C when the installation angle is greater than
45
°
and less than 75
°
off horizontal (excluding the memory card).
(4) The ambient operating temperature is 0 to 50
°
C when the installation angle is greater than
75
°
and less than 90
°
off horizontal (excluding the memory card).
Summary of Contents for NSA
Page 2: ......
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...xx...
Page 25: ...Section 1 Overview and Specifications...
Page 33: ...Section 2 Nomenclature...
Page 38: ...2 1 Nomenclature 2 1 3 Connectors and Interfaces 2 6 2 Nomenclature...
Page 39: ...Section 3 Installing the NSA series Industrial PC and Connecting Peripheral Devices...
Page 59: ...Section 4 RAS Functions...
Page 73: ...Section 5 Maintenance...
Page 81: ...Appendix...