background image

6

Three-phase Voltage Relay

 

K8AB-PW

Cat. No. N148-E1-01

Safety Precautions

Precautions for Safe Use

Make sure to follow the instructions below to ensure safety.

1.

Do not use or keep this product in the following environments.

Outdoors, or places subject to direct sunlight or wearing 
weather.

Places where dust, iron powder, or corrosive gases (in 
particular, sulfuric or ammonia gas) exist.

Places subject to static electricity or inductive noise.

Places where water or oil come in contact with the product.

2.

Make sure to install this product in the correct direction.

3.

There is a remote risk of electric shock. Do not touch terminals 
while electricity is being supplied.

4.

Make sure to thoroughly understand all instructions in the 
Instructions Manual before handling this product.

5.

Make sure to confirm terminal makings and polarity for correct 
wiring.

6.

Tighten terminal screws firmly using the following torque.
Recommended torque: 0.54 N·m

7.

Operating ambient temperature and humidity for this product 
must be within the indicated rating when using this product.

8.

There is a remote risk of explosion. Do not use this product where 
flammable or explosive gas exists.

9.

Make sure that no weight rests on the product after installation.

10.

To enable an operator to turn off this product easily, install 
switches or circuit breakers that conform to relevant requirements 
of IEC60947-1 and IEC60947-3, and label them appropriately.

Precautions for Correct Use

For Proper Use

1.

Do not use the product in the following locations.

Places subject to radiant heat from heat generating devices.

Places subject to vibrations or physical shocks.

2.

Make sure to use setting values appropriate for the controlled 
object. Failure to do so can cause unintended operation, and may 
result in accident or corruption of the product.

3.

Do not use thinner or similar solvent for cleaning. Use commercial 
alcohol.

4.

When discarding, properly dispose of the product as industrial 
waste.

5.

Only use this product within a board whose structure allows no 
possibility for fire to escape.

About Installation

1.

When wiring, use only recommended crimp terminals.

2.

Do not block areas around the product for proper dissipation of 
heat. (If you do not secure space for heat dissipation, life cycle of 
the product will be compromised.)

3.

To avoid electrical shocks, make sure that power is not supplied to 
the product while wiring.

4.

To avoid electrical shocks, make sure that power is not supplied to 
the product when performing DIP switch settings.

Noise Countermeasures

1.

Do not install the product near devices generating strong high 
frequency waves or surges.

2.

When using a noise filter, check the voltage and current and 
install it as close to the product as possible.

3.

In order to prevent inductive noise, wire the lines connected to the 
product separately from power lines carrying high voltages or 
currents. Do not wire in parallel with or on the same cable as 
power lines. 
Other measures for reducing noise include running lines along 
separate ducts and using shield lines.

To avoid faulty operations, 
malfunctions, or failure, observe the 
following operating instructions.

1.

When turning on the power, make sure to realize rated voltage 
within 1 second from the time of first supply of electricity.

2.

Make sure to use power supply for operations, inputs, and 
transformer with the appropriate capacity and rated burden.

3.

Maintenance and handling of this product may only be performed 
by qualified personnel.

4.

Distortion ratio of input wave forms must be 30% or less. Use of 
this product with circuits that have large distortion in wave forms 
may result in unwanted operations.

5.

Using this product for thyristor controls or inverters will result in 
errors.

6.

When setting the volume, adjust the control from the minimum 
side to the maximum side.

Summary of Contents for K8AB-PW

Page 1: ...possible for overvoltages and undervoltages World wide power specifications supported by one Unit switchable Relay warning status easily monitoring using LED indicator Easy wiring with ferrules 2 2 5...

Page 2: ...ltage and undervoltage Operating value setting range Overvoltage 30 to 25 of maximum rated input voltage Undervoltage 30 to 25 of maximum rated input voltage Note The rated input voltage is switched w...

Page 3: ...ged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsell 5Y8 1 ivory Case...

Page 4: ...22 21 Over voltage alarm Under voltage alarm Load The power supply is shared with the rated in put voltage Power indicator Relay status indicator Overvoltage knob OVER Undervoltage knob UNDER Operati...

Page 5: ...hase 4 wire power monitoring mode SW3 SW4 Function Default 3 phase 3 wire mode 3 phase 4 wire mode SW3 SW4 OFF OFF Rated input voltage switch K8AB PW1 200 VAC 115 VAC OFF OFF ON OFF 220 VAC 127 VAC OF...

Page 6: ...roduct 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board whose st...