No.
Display
Name
Function
12
ALM LED Light
Refer to LED Screen Displays on page 55
.
13
REV LED Light
14
DRV LED Light
15
FOUT LED Light
u
Digital Text Display
Text appears on the LED Operator as shown below. This section explains the meaning of text as it appears on the display
screen.
Lit
Flashing
Table 4.2 Digital Text Display
Text
LED
Text
LED
Text
LED
Text
LED
0
9
I
R
1
A
J
S
2
B
K
T
3
C
L
U
4
D
M
<1>
V
5
E
N
W
<1>
6
F
O
X
none
7
G
P
Y
8
H
Q
Z
none
<1> Displayed in two digits.
u
LED Screen Displays
Display
Lit
Flashing
Off
When the drive detects an alarm or error
• When an alarm occurs
• oPE detected
Normal state (no fault or alarm)
Motor is rotating in reverse
—
Motor is rotating forward
Drive Mode
—
Programming Mode
Displays output frequency (Hz)
—
—
As illustrated in
this manual
STOP
u
LO/RE LED and RUN LED Indications
LED
Lit
Flashing
Flashing Quickly
<1>
Off
When run command is
selected from LED operator
(LOCAL)
—
—
Run command is selected from
device other than LED operator
(REMOTE)
During run
• During deceleration to stop
• When a run command is input
and frequency reference is 0
• During deceleration at a fast-
stop.
• During stop by interlock
operation.
During stop
As shown
<1> Refer to
Figure 4.1
for the difference between “flashing” and “flashing quickly”.
4.2 Using the Digital LED Operator
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
55
4
Start-Up Programming & Operation