353
Auxiliary Area Allocations
Appendix D
A559
00 to 15 Number of Analog Samples
Indicates the number of data samples actually input since sam-
pling started.
A560
00 to 15 Analog Output 1 Output Value
When an END refresh is selected, the 4-digit hexadecimal value
set here by the user is output from analog output port 1.
When immediate refreshing is selected, the 4-digit hexadecimal
value being output from analog output port 1 is stored here for
monitoring. The output value range depends on the output range,
as shown below.
• 0 to 10 V, 0 to 5 V or 1 to 5 V: FF38 to 1068 hex
•
−
10 to 10 V: EA84 to 157C hex
Note
1. Set the analog output method (END or immediate refreshing)
with the System Setup’s output method setting. A setting of 0
hex specifies an END refresh. This setting applies to both ana-
log output 1 and 2.
2. Specify the output range with the output 1 setting.
A561
00 to 15 Analog Output 2 Output Value
This word has the same settings as the analog output 1 output
value (A560), above. (When an END refresh is selected, set the
value to output from analog output port 2. When an immediate
refresh is selected, the output value is stored here for monitoring.)
Note
1. Set the analog output method (END or immediate refresh) with
the System Setup’s output method setting. A setting of 0 hex
specifies an END refresh. This setting applies to both analog
output 1 and 2.
2. Specify the output range with the output 2 setting.
A562
00
Analog Output 1 Flags
User Adjustment
Completed
Initial value is 0.
Set to 1 if user performs offset/gain adjustment and Returns to
factory default setting of 0 if adjustment value is cleared.
04
Operating
ON: ON while the analog output is being changed by ACC(888).
OFF: Turned OFF when target value is reached.
08
Output SV Error
ON: ON when the output SV setting is outside of the allowed set-
ting range.
OFF: OFF when the output SV is within range.
12
Factory Adjust-
ment Value
Error
ON: ON when the factory-set data stored in flash memory is
invalid.
OFF: OFF when the factory-set data stored in flash memory is
normal.
14
User Adjustment
Value Error
ON: ON when the user-set adjustment value stored in flash mem-
ory is invalid.
OFF: OFF when the user-set adjustment value stored in flash
memory is normal.
A563
00
Analog Output 2 Flags
User Adjustment
Completed
Same as for Analog Output 1 Flags.
04
Operating
08
Output SV Error
12
Factory Adjust-
ment Value
Error
14
User Adjustment
Value Error
A564
00
Analog Output 1 Conversion Enable Bit
ON: Enables D/A conversion (enables analog output).
OFF: Disables D/A conversion (analog values output according to
Output Stop Function specification in System Setup).
Note
This bit is cleared when the Modules operating mode is
changed between RUN or MONITOR mode and PROGRAM
mode.
A565
00
Analog Output 2 Conversion Enable Bit
ON: Enables D/A conversion (enables analog output).
OFF: Disables D/A conversion (analog values output according to
Output Stop Function specification in System Setup).
Note
This bit is cleared when the Modules operating mode is
changed between RUN or MONITOR mode and PROGRAM
mode.
Address
Bits
Name
Function
Summary of Contents for HOME SECURITY SYSTEM - MOTION SENSOR FQM1-CM001
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 11: ...xii...
Page 23: ...xxiv Data Backup 5...
Page 53: ...30 Function Tables Arranged by Purpose Section 1 7...
Page 71: ...48 Memory Block Diagram Section 2 7...
Page 254: ...231 Analog Outputs Section 7 10...
Page 255: ...232 Analog Outputs Section 7 10...
Page 263: ...240 Connecting the CX Programmer Section 8 2...
Page 285: ...262 Inspections Section 10 1...
Page 397: ...374 Auxiliary Area Allocations Appendix D...
Page 409: ...386 Index...
Page 411: ...388...