1. Partial control of machine
1-1 Parts Processing Machine
The entire device stops when the Emergency Stop Switch is pressed.
Only the processing section stops when the Safety Light Curtain is interrupted.
Required Units
Unit
Qty.
Safety input to be applied
Page
G9SX-BC
1
Emergency Stop Switch
39
G9SX-AD
1
Safety Light Curtains
40
(2) Safety Light Curtain
Processing section
Stop
Segment A
Basic Unit
G9SX-BC
(1) Emergency Stop
Switch
(1) Emergency Stop
Switch
Segment B
(2) Safety Light
Curtain
Processing section
Advanced Unit
G9SX-AD
Segment A
Segment A
Segment B
Stop Stop
Segment B
Stop
Operation Example
(2) Safety Light Curtain is
interrupted.
(1) The Emergency Stop Switch
is pressed.
Logical AND connection