1. Partial control of machine
G9SX
USER'S GUIDE
13
A
p
plica
tion Examples
Section
1
■
Timing chart
(1) Before operation is started.
(2) Main door is unlocked and opened, and then work is performed.
(3) Restart operation after the main door is closed.
(4) The pallet changer door opens and the pallet changer section stops.
(5) The pallet changer door is closed and the pallet changer is reset.
(6) The tool changer door opens and the tool changer section stops.
(7) The tool changer door is closed and the tool changer section is reset.
(8) If the Emergency Stop Switch is pressed, the upper unit and lower units will stop.
Emergency Stop Switch S1
Reset switch S2
Logical AND output L1
KM1, KM2 NC contact
KM1, KM2 NO contact
Logical AND input T41
Logical AND input T41
Logical AND input T41
KM3, KM4 NC contact
KM3, KM4 NO contact
Safety Limit Switch S4
Safety Door Switch S7
Safety Door Switch S8
Reset switch S6
Operation command
Rotation of motor
Operation command
Rotation of motor
Operation command
Rotation of motor
OFF-delay time
OFF-delay time
OFF-delay time
OFF-delay time
OFF-delay time
OFF-delay time
Door can be opened.
Stop signal
Lock release signal
Lock release switch S5
Guard Lock Safety Door Switch S3
(1)
(2)
(3)
(8)
(4)
(5)
(6)
(7)
G9SX-BC202 (upper unit)
KM5, KM6, NC contact
KM5, KM6, NO contact
KM7, KM8, NC contact
KM7, KM8, NO contact
G9SX-AD322-T15 (lower unit : Main door)
G9SX-AD322-T15 (lower unit : Pallet changer door)
G9SX-AD322-T15 (lower unit : Tool changer door)
Summary of Contents for G9SX Series
Page 50: ...MEMO 50 G9SX USER S GUIDE ...
Page 95: ...G9SX USER S GUIDE 95 Precautions Precautions ...
Page 101: ...MEMO G9SX USER S GUIDE 101 ...