![background image](http://html1.mh-extra.com/html/omron/g9sx-series/g9sx-series_user-manual_742388011.webp)
1. Partial control of machine
G9SX
USER'S GUIDE
11
A
p
plica
tion Examples
Section
1
1-2 Machining Center
When the Emergency Stop Switch is pressed, the entire machine will stop.
When a door is open, the corresponding part will not be activated.
Required Units
Unit
Qty.
Safety input to be applied
Page
G9SX-BC
1
Emergency Stop Switch
39
G9SX-AD
3
Guard Lock Safety Door Switch
Safety Door Switches (Set of two)
40
Segment A
Segment B
Segment C
(4) Tool changer door
(3) Pallet changer door
(1) Emergency Stop
Switch
(2) Main door
Segment A
Segment B
(1) The Emergency Stop
Switch is pressed.
Stop Stop
Segment C
Stop
Segment A
Segment B
(2) The main door is opened.
Stop
Stop
Segment C
Stop
Segment A
Segment B
(3) The pallet changer door
is opened.
Stop
Stop
Segment C
Stop
Segment A
Segment B
(4) The tool changer door is
opened.
Stop Stop
Segment C
Stop
Operation Example
Advanced Unit
G9SX-AD
Advanced Unit
G9SX-AD
Advanced Unit
G9SX-AD
(3) Pallet Changer Door
(4) Tool Changer Door
Safety Door
Switch
Safety Door
Switch
Basic Unit
G9SX-BC
(2) Main Door
Logical AND connection
(1) Emergency Stop
Switch
Guard Lock
Safety Door
Switch
Summary of Contents for G9SX Series