background image

G70D-B7A

G70D-B7A

48

G3DZ-2R6PL (Power MOS FET Relay Mounted to G70D-R6M

j

1-B7A)

Load Current vs. Ambient Temperature

Inrush Current Resistivity (Non-repetitive)

(The value will be less than half for repetitive
inrush currents.)

Note:

The above graph shows the characteris-
tics for the Relay when it is mounted to
the G70D.

Note:

The above graph shows the characteris-
tics for the Relay when it is mounted to
the G70D.

Ambient temperature (

°

C)

Energizing time (ms)

Load current (A)

Inrush current (A. Peak)

Operation

 I/O Combinations

Screw terminal model
 (32 points)

Input (Transmission)

Output (Reception)

Input (Transmission)

Relay output model 
(16 points)

G70D-B7A

Note:

Not connectable to high-
speed B7A models.

Screw terminal model

(16 output points)

Modular model (16 points)

B7A

Hybrid IC model (16 points)

B7AH

PLC connector model
 (16 points)

B7A

PLC connector model 
(32 points)

B7A

B7A

B7AS

B7AS

Summary of Contents for G70D B7A Series

Page 1: ...g Information Product List Classification Number of I O points Rated voltage I O delay time Error processing Model Relay output 16 SPST NO 16 24 VDC Normal typical 19 2 HOLD See note 2 G70D R6R11 B7A e ay ou u 6 S S O 6 C o a y ca 19 2 ms See note 1 LOAD OFF See note 3 G70D R6R31 B7A Power MOS FET l t t HOLD See note 2 G70D R6M11 B7A o e OS relay output LOAD OFF See note 3 G70D R6M31 B7A Note 1 No...

Page 2: ...5 Hz 0 75 mm double amplitude for 2 hours each in X Y and Z directions Shock resistance Destruction 300 m s2 S oc es s a ce Malfunction 100 m s2 Operating voltage range 24 VDC 10 15 Current consumption See note 2 24 VDC approx 300 mA Cable length between Unit and connected device Depends on the load Color of indicators Operation indicator orange Power supply indicator green red for errors Coil sur...

Page 3: ...ating 0 to 55 C Storage 20 to 65 C Ambient humidity Operating 35 to 85 Mounting strength No damage when 49 N pull is applied for 1 s each in all directions only 9 8 N pull in direction of DIN track Terminal strength Tightening strength 0 78 to 0 98 N m Tensile strength 49 N for 1 minute Weight Approx 230 g Note 1 The values above are for the Terminal in its initial state 2 The value given for curr...

Page 4: ...Z Power MOS FET Relay Rated voltage Operating voltage Must operate voltage level Must release voltage level Input impedance Rated current 24 VDC 19 2 to 28 8 VDC 19 2 VDC max 1 VDC max 4 kΩ 20 8 2 mA 20 Note The rated current includes the Link Terminal s LED current Output for each G3DZ Power MOS FET Relay Load voltage Load current Inrush current 3 to 264 VAC 3 to 125 VDC 100 µΑ to 0 3 A 6 A 10 ms...

Page 5: ...raph shows the characteris tics for the Relay when it is mounted to the G70D Ambient temperature C Energizing time ms Load current A Inrush current A Peak Operation I O Combinations Screw terminal model 32 points Input Transmission Output Reception Input Transmission Relay output model 16 points G70D B7A Note Not connectable to high speed B7A models Screw terminal model 16 output points Modular mo...

Page 6: ...r See note Note The above diagram is for G70D R6Rj1 B7A models G6D mounting With G70D R6Mj1 B7A models G3DZ Power MOS FET Relays are used Terminal Arrangement G70D R6jjj B7A Power supply Load Load Load Load Load Load Load Load Power supply Power supply Power supply Power supply Power supply Power supply Power supply Load Load Load Load Load Load Load Load 24 VDC Note 1 Internal connections are ind...

Page 7: ...ink Terminals use 24 VDC G6D 1A Relays and G70D R6Mj1 B7A Link Terminals use 24 VDC G3DZ 2R6PL Relays When replacing relays use the yellow Relay Removal Tool at the corner of the screw terminal except for G7TC Do not mount or dismount relays with the power supplied Opening the Front Cover Rotating Type Hold the two bottom corners of the front cover labelled A in the dia gram below and lift upwards...