When Using Intermediate Brackets Only (Free-Location Mounting)
Backside mounting
Bracket mounting procedure (Mounting) p.67
The alignment range of the Intermediate Bracket must be ±30°.
[ Unit : mm ]
15
22
7
F
42
5.5
275 max
275 max
C (Protective height)
43
30 30
Intermediate Bracket
(F39-LJB2)
Intermediate Bracket
(F39-LJB2)
22
42
4-M5
42
F
C
Dimensions C and F
Dimensions F
C
4-digit number of the type name (protective height)
F
Depends on the protective height. See the table below.
Protective height
Number of Intermediate Brackets
Dimensions F
0185 to 0225
1
-
0305 to 1105
2
555 mm max.
1185 to 1585
3
555 mm max.
1665 to 2065
4
555 mm max.