33
F3SJ-E/B
User’s Manual
Chapter
2
Des
c
ript
io
n o
f Fun
ction
s
System Configuration and Functions
E
• Use sensors with mutual interference prevention (such as retro-reflective E3Z-R
series)
• Use laser-type sensors (such as laser-type E3Z-LR
series)
• Take distance from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them
crosswise)
• Install a physical barrier
• Attach interference prevention filter (provided for E3Z series as accessories)
• Attach a slit to reduce light intensity (provided for E3Z series as accessories)
• Lower the sensitivity
• Reduce a distance between a workpiece and a muting sensor to prevent reflected light from a
workpiece
(2) Interference to a muting sensor from F3SJ-B
• Take distance (D) from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them
crosswise)
• Install a physical barrier
• Arrange sensors in alternation
• Lower the sensitivity
(3) Interference to F3SJ-B from a muting sensor
• Use a red LED type sensor (such as retro-reflective E3Z-R
series)
• Use laser-type sensors (such as laser-type E3Z-LR
series)
• Take distance (D) from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them
crosswise)
• Install a physical barrier
• Arrange sensors in alternation
• Attach a slit to reduce light intensity (provided for E3Z series as accessories)
Mutual interference between a muting sensor and F3SJ-B in (2) and (3) above can be prevented by
configuring D satisfying a formula shown below:
•If L = 0.2 to 3 m
D = 0.26 m or larger
•If L = 3 m or larger
D = L x tan5° = L x 0.088 m or larger
L : Distance between an emitter and a receiver of the F3SJ-B
D : Distance between a muting sensor and a F3SJ-B
Summary of Contents for F3SJ-B0185P25
Page 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Page 12: ...x Introduction F3SJ E B User s Manual...
Page 16: ...xiv Introduction F3SJ E B User s Manual...
Page 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Page 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Page 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...