87
F3SJ-E/B
User’s Manual
Ch
apt
e
r
3
Wi
ring
Wiring/Installation
E
Internal Wiring Diagram (Optional: F39-CN5)
When you need to use a cable that is not specified by OMRON, use a cable that satisfies the following
specifications.
<Extension cable>
Easy Type
1. Emitter : 5-wire (0.12 mm
2
or larger x 1 pair, 0.12 mm
2
or larger x 3, conductor resistance 0.146
ohms/m max.)
Receiver : 6-wire (0.12 mm
2
or larger x 3 pairs, conductor resistance 0.146 ohms/m max.)
2. Emitter : Communication lines (+) and (-) must be used as twisted-pair lines.
Receiver : Communication lines (+) and (-), safety output lines 1 and 2 must be used as twisted-pair
lines.
Basic Type
1. 8-wire (0.3 mm
2
or larger x 4 pairs, conductor resistance 0.058 ohms/m max.)
2. Braided shield
3. Connect the pin No. 7 with the shield line.
4. Communication lines (+) and (-), 24 V and 0 V lines must be used as twisted-pair lines.
Do not use cables in the same conduit as high voltage or electric power lines.
1
2
3
4
5
6
7
8
1
7
8
2
3
4
5
6
1
7
8
2
3
4
5
6
2
3
8
1
7
6
5
4
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
White
Brown
Black
Yellow
Grey
Pink
Blue
Red
Female
Female
White
Brown
Black
Yellow
Grey
Pink
Blue
Red
Male
Connected to emitter's connection cable
and Cable with connectors on both ends
Connected to receiver's connection cable
and Cable with connectors on both ends
0V
+24V DC
Test input
Reset input
Safety output 1
Safety output 2
Communication line (+)
Communication line (-)
Summary of Contents for F3SJ-B0185P25
Page 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Page 12: ...x Introduction F3SJ E B User s Manual...
Page 16: ...xiv Introduction F3SJ E B User s Manual...
Page 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Page 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Page 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...