
47
F3SJ-E/B
User’s Manual
Ch
apt
e
r
3
Dimen
s
ions
Wiring/Installation
E
When Using Top/Bottom and Intermediate Brackets
Backside mounting
Bracket mounting procedure (Mounting) p.67
- If the protective height is 1105 mm or more, use Intermediate Brackets of specified quantities and locations
according to the dimensions. If the brackets described above are not used, ratings and performance cannot be met.
- When you use a sensor in a situation where the sensor is under a load, add an Intermediate Bracket.
P
(beam
gap)
[ Unit : mm ]
13.4
22.5
34.5
B
A
5.5
30
19
6.5
dia.9
7.5
18.3
7
22
30
30
D
53
42
C (Protective height)
30
13
2
43
6.5
45
<M5 screw fixed>
<M8 screw fixed>
Top/Bottom Bracket
(F39-LJB1)
Top/Bottom Bracket
(F39-LJB1)
Intermediate Bracket
(F39-LJB2)
2
E
19
B
B
E
C
C
E
42
42
5.9
5.9
22
22
4-M5
2-M8
2-M5
2-M5
Dimensions A to E and P
Dimensions E
* Value E must be 700 mm or less when not using value E obtained from the calculation above.
A
C+69
B
C+42.2
C
4-digit number of the type name (protective height)
D
C-45
E
Depends on the protective height. See the table below.
P
20
Protective height
Number of Intermediate Brackets
Dimensions E
0185 to 1105
0
-
1185 to 1345
1
C/2 max.
1425 to 2065
2
C/3 max.
Summary of Contents for F3SJ-B0185P25
Page 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Page 12: ...x Introduction F3SJ E B User s Manual...
Page 16: ...xiv Introduction F3SJ E B User s Manual...
Page 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Page 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Page 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...