Ratings/Specifications
The model names of the F3SJ-E/B contain the 4 digits indicating the protective height (mm).
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety
output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
*3. The Vs indicates a voltage value in your environment.
Item
Model
Easy Type
Basic Type
F3SJ-E
P25
F3SJ-B
P25
Detection capability
Opaque objects
25 mm diameter
Beam gap
20 mm
Number of beams
8 to 54
8 to 102
Protective height
185 to 1,105 mm
185 to 2,065 mm
Lens diameter
5 mm
Operating range
0.2 to 7 m
Response time
ON to OFF: 15 ms max. (Response time when used alone or in 2 or 3 connected)
OFF to ON: 70 ms max. (Response time when used alone or in 2 or 3 connected)
Startup waiting time
2 s max.
Power supply voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current consumption
Refer to "Model/Current Consumption List" on page 8.
Light source
Infrared LED (870 nm wavelength)
Effective aperture angle (EAA)
Based on IEC 61496-2.
Within ±2.5° for both emitter and receiver at an operating range of 3 meters or more.
Safety output (OSSD)
Two PNP transistor outputs, Load current: 200 mA max., Residual voltage: 2 V max.
(except for voltage drop due to cable extension), Leakage current: 1 mA max., Load
inductance: 2.2 H max. *1
Maximum capacitive load: 1 µF *2
Auxiliary output
–
One PNP transistor output
Load current: 100 mA max.
Residual voltage: 2 V max.(except for voltage
drop due to cable extension)
Leakage current: 1 mA max.
Output operation mode
Safety output: ON when receiving light
Safety output: On when receiving light
Auxiliary output:
- Basic system
Reverse output of safety output
- Muting system
ON during muting/override
Input voltage
Test input and reset input are both:
ON voltage: Vs-3V to Vs *3 (sink current 3mA max.)
OFF voltage: 0V to 1/2Vs, or open *3
External device monitoring input is:
ON voltage: Vs-3V to Vs *3 (sink current 5mA max.)
OFF voltage: 0V to 1/2Vs, or open *3
Test input, interlock selection input, reset input, and
muting input are all:
ON voltage: Vs-3V to Vs *3 (sink current 3mA max.)
OFF voltage: 0V to 1/2Vs, or open *3
External device monitoring input is:
ON voltage: Vs-3V to Vs *3 (sink current 5mA max.)
OFF voltage: 0V to 1/2Vs, or open *3
Overvoltage category
II (IEC 60664-1)
Indicator
Refer to "Internal (LED) Indicator Display Pattern" on page 4.
Mutual interference prevention function
Mutual interference prevention algorithm prevents interference in up to three sets.
Series connection function
–
Number of connections: Up to three sets
Total number of beams: Up to 192
Maximum connection cable length: 7 m
Test function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-related functions
–
Interlock (basic system)
External device monitoring (basic system)
Muting (muting system)
Override (muting system)
Summary of Contents for F3SJ-B0185P25
Page 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Page 12: ...x Introduction F3SJ E B User s Manual...
Page 16: ...xiv Introduction F3SJ E B User s Manual...
Page 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Page 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Page 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...