13
F3SG-SR-K
Quick Installation Manual
output, 0 VDC line of the power supply must not be grounded.
Wiring must not be bent, cracked, nor damaged.
- Operation Check While the Machine Is Stopped
The test rod is not deformed.
The object resolution may vary depending on the models of the F3SG-SR-K and settings of the Floating
Blanking function or Reduced Resolution function. Use a test rod with an appropriate diameter for
inspection. A test rod is not included in the F3SG-SR-K product package. The model name of test rod is
as follows.
* The customer needs to prepare a test rod lager than 25-mm dia.
The sensor must detect a test rod wherever it is in the detection zone. In other words, when a test rod is
inserted into the detection zone, the OSSD indicator turns red.
When the Fixed Blanking function is used, you must ensure that all blanked zones in the detection zone
are covered by a hard barrier guard and there must be no zone in the detection zone where the test rod
goes undetected.
To check detection, move the test rod as shown in the diagram below.
When the External Test function is used:
When PNP is selected, the OSSD indicator turns red when the TEST line is short-circuited to 9 V to Vs.
When NPN is selected, the OSSD indicator turns red when the TEST line is short-circuited to 0 to 3 V.
When the External Device Monitoring function is used:
When the RESET line is open the OSSD indicator remains red regardless of the beam state of the F3SG-
SR.
When the Start Interlock function is used:
When the F3SG-SR-K is turned ON and the F3SG-SR-K is unblocked, the OSSD indicator remains red.
The reset input turns the OSSD indicator to green.
When the Restart Interlock function is used:
When the OSSD indicator is green and the F3SG-SR-K is blocked and then returned to unblocked state,
the OSSD indicator remains red. The reset input turns the OSSD indicator to green.
When the Muting function is used, minimum muting time limit required must be set.
When the Muting function's operation mode is Exit-Only Muting mode, minimum muting end wait time
required must be set.
Under the MUTING state, a signal that indicates the MUTING state must be given from the AUX line.
When the Override function is used, the minimum override time limit required must be set.
Under the OVERRIDE state, a signal that indicates the OVERRIDE state must be given from the AUX
line.
Model name
Diameter *
F39-TRD14
Dia. 14 mm
F39-TRD25
Dia. 25 mm
Start
Stop
Mounting
Wiring
Operation check