![background image](http://html1.mh-extra.com/html/omron/e3x-nl/e3x-nl_datasheet_741200007.webp)
A-203
E3X-NL
E3X-N
L
Operation
Sensitivity setting
Two-point teaching
Pro
ce-
dur
e
Setting
Operation
1
---
Locate the sensor head within the sensing
distance.
2
Move the mode selector to the
position.
3
Press the teaching button once with a
sensing object located under the sensor
as shown in the following illustration.
4
With an object absent (ground), press the
TEACHING button (second time).
If teaching is OK
If teaching is NG
5
Move the mode selector to the
po-
sition. Sensitivity setting is complete.
6
Light Dark
Select the desired operation
format with the operation mode selector
(L.ON/D.ON).
TEACH
ON
RUN
TIMER
OFF
TEACH
TEACH
Object
Base
Teaching indicator ... Lit red
The built-in buzzer beeps once.
TEACH
Object
Base
Teaching indicator ... Lit red
Lit green
The built-in buzzer beeps once.
Teaching indicator ... Lit red
Flickers
red
The built-in buzzer beeps 3 times.
Change the object position and setting
distance again and make setting in order of
1 to 4.
TEACH
ON
RUN
TIMER
OFF
RUN
Teaching indicator ... Lit green
Extin-
guished
L.ON
D.ON
One-point teaching
Pro
ce-
dur
e
Setting
Operation
1
Move the mode selector to the
position.
2
Press the teaching button with one of the
sensing objects or the background object
located under the sensor for sensing.
3
Move the mode selector to the
po-
sition. 1-point teaching setting is complete
as soon as the first object passes.
4
Select the desired operation format with
the operation mode selector (L.ON/D.ON).
TEACH
ON
RUN
TIMER
OFF
TEACH
Teaching indicator ... Lit red
The built-in buzzer beeps once.
TEACH
ON
RUN
TIMER
OFF
RUN
Teaching indicator ... Lit red
Lit
green
L.ON