background image

A-205

E3X-NL

E3X-N

L

Remote teaching function

In remote teaching, the remote RUN/TEACH input signal is

used for teaching instead of the mode selector and the remote

teaching input signal is used instead of the teaching button.

Miscellaneous

EEPROM Write Error

If a write error occurs (buzzer beeps, red and green teaching

indicators flicker at the same time, operation and stability indi-

cators flicker) due to power-off, static electricity or other noise

in the teaching mode (until the initial operation level compen-

sation completion of teaching without object), perform teach-

ing again with the unit button.

Note: If a memory error occurs, the red and green teaching indicators flicker at

the same time and the stability indicator flickers, unlike the teaching error.

Pro-

ce-

dure

Operation

1

Set the mode selector to 

.

2

The following signal conditions must be given as remote
teaching input conditions.

A

 If there is a teaching error after performing remote two-

point teaching with E3X-NL, try performing remote two-
point teaching again. If the remote RUN/TEACH input is
set from L to H after the teaching error, the thresholds set
with E3X-NL will not be refreshed.

B

 When remote teaching is not performed, cut the pink and

purple wires at the root of the cable or connect them to the
+ side (+V) of the power supply, and cut the orange wire
at the root of the cable or connect it to GND (0 V).

C

 About 1 s after remote teaching is over, the Sensor is

made ready to detect an object.

RUN

Brown  

+

V

Blue  0V

Black  Control output

Orange  Answer-back output

Purple  Remote teaching input

Pink Remote 
   RUN/TEACH input

T2 * 1.0 to 1.3s

1.0 to 1.3s

T1

T1

T2

T1 *

* Note: T1 must be 20 ms minimum and T2 must be 500 ms minimum at the time of remote

teaching.

0.5s

0.5s

0.5s

0.5s 0.5s 0.5s

0.1s

0.1s

H

L

H

L

H

L

H

L

Remote 
RUN/TEACH input

Remote 
teaching input

Answer-back output

(If teaching is OK.)

Answer-back output

(If teaching is NG.)

T2 * 1.0 to 1.3s

T1

T1 *

0.5s

H

L

H

L

H

L

Remote 
RUN/TEACH input

Remote 
teaching input

Answer-back output

(Remote 1-point teaching)

(Remote 2-point teaching)

Summary of Contents for E3X-NL -

Page 1: ...can choose the short distance small spot type ideal for detection of small objects or the long distance type that can perform in line standard detection Adopts the pulse ON system that is insensi tive...

Page 2: ...erence like an ordinary mark sensor When 2 point teaching is selected Measures against Double Refraction There are transparent films and transparent plastic objects that change the direction of polari...

Page 3: ...1 m E32 S15 2 0 5 m E32 S15L 1 1 m E32 S15L 2 Shape Model Quantity Remarks E39 L109 1 Can be used with the fiber unit E32 S15 Mounting bracket vari able in rotary angle 0 45 for sta ble detection of t...

Page 4: ...h 1 000 VAC at 50 60 Hz for 1 minute Vibration resistance 10 to 55 Hz 1 5 mm double amplitude or 300 m s2 approx 30G for 2 hrs each in X Y and Z directions Shock resistance Destruction 500 m s2 for 3...

Page 5: ...hite glossy plastic Sensing object 40 20 mm 140 120 100 80 60 40 20 0 Angle 15 10 5 0 5 10 15 10mm Relative glossiness White drawing paper White glossy plastic Sensing object 40 20 mm 140 120 100 80 6...

Page 6: ...energy between the two teaching points to deter mine the thresholds setting with E3X NL As shown in the following table if there is only a small difference in glossiness but there is a large differenc...

Page 7: ...Object Base Teaching indicator Lit red Lit green The built in buzzer beeps once Teaching indicator Lit red Flickers red The built in buzzer beeps 3 times Change the object position and setting distan...

Page 8: ...ects have color patterns the difference in glossi ness among the inks on the sensing objects may influence the sensing operation of E3X NL Therefore perform two point teaching with E3X NL at a place w...

Page 9: ...or after performing remote two point teaching with E3X NL try performing remote two point teaching again If the remote RUN TEACH input is set from L to H after the teaching error the thresholds set wi...