E2CY
E2CY
12
J
INDICATORS
Operation Indicator (Orange)
The operating indicator will turn ON when the control output is ON.
Excess Gain Level Indicators (Green and Orange)
The excess gain level indicators will be ON according to the distance of the target object as shown below.
OFF
ON
Threshold level
Short distance
Long distance
Note: 1. All indicators will be ON if the target object is at a position of approximately 80% of the preset sensing distance.
2. All indicators will be OFF at a position of approximately 110% of the preset sensing distance.
(See Note 1.)
(See Note 2.)
Green
Orange
Position of
target
objects
<Excess Gain Level>
Installation
J
CONNECTION
Sensor Head
Shielded wire
Conductor
Amplifier Unit
Control output
Self-diagnostic
output
Connection of Sensor Head and Amplifier Unit
Brown
Black
Blue
Orange
12 to 24 VDC
0 V