E2CY
E2CY
3
Operation
J
OUTPUT CIRCUIT
Self-diagnostic output:
100 mA max.
12 to 24 VDC
100 mA max.
0 V
39 V
Brown
Black
Blue
Orange
39 V
Main
circuit
Load
Control output
J
SENSITIVITY ADJUSTMENTS
Sensitivity adjustment is performed with or without a target object by setting the Sensor to the maximum sensing distance. The distance
can be set by using any of the following four methods.
Types of Sensing Adjustments and Applications
No.
Distance adjustment method
Application
Operation mode
selector
1
Teaching without sensing object
The E2CY is used as a normal proximity sensor.
T
2
Teaching with or without the sensing
object
•
The E2CY is used for detecting the difference in target object level.
•
The E2CY is used for discriminating types of target objects.
•
The E2CY is used for discriminating the distance between the
sensing surface and target objects located within a certain range.
3
Positioning teaching
•
Object positioning is required.
•
The designation of sensor-ON point is required.
4
The distance is adjusted automatically
The E2CY is used as a normal proximity sensor.
AUTO
Note: All teaching methods can eliminate the influence of surrounding metal objects.