Specifications Table

-- continued from previous page

Part number

E2CY-X1R5A

E2CY-C2A

E2CY-V3A

Ambient humidity

Operating

35% to 95%

Vibration resistance

Destruction: 10 to 500 Hz, 2.0-mm double amplitude or 150 m/s

2

(approx. 15G)

for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

(approx. 50G) three times each in X, Y, Z directions

Enclosure rating

IEC IP67

Connecting cable length

Coaxial cable with a standard length of 3 m for high-frequency use

Compensation range of cable length characteristic

0.5 to 5 m (See Note.)

Material

Case

Stainless steel

Zinc die-cast

Sensing surface

Heat-resistant ABS resin

Cable

Soft vinyl chloride

Weight (packaged state)

Approx. 35 g (with 3 m cord)

Accessories

M5 nut with toothed

washer

---

M2 screw, hexagonal nut,

spring washer, and flat

washer

Note: When extending the cable, use a 1.5D-2V (equivalent to JIS C 3501) cable with characteristic impedance of 50

.

Amplifier Unit

Supply voltage

12 to 24 VDC

±

10%, ripple (p-p):

±

10% max.

Current consumption

40 mA max.

Sensing distance adjustment range

10% min. of stable sensing distance

Adjustment method

Teaching

Differential travel

10% max. of sensing distance in FINE mode.

15% max. of sensing distance in NORM mode.

Response time

Refer to the response frequency of the Sensor Head in use.

Control output

NPN open collector output of 100 mA max. with a max. residual voltage of 1 V

Self-diagnostic output

NPN open collector output of 100 mA max. with a max. residual voltage of 1 V

Circuit protection

Reverse polarity, surge voltage, and load short-circuit (for both control output and

diagnosis output)

Cable length

2 m, pull-out cable

Cable length compensation

Freely cut or extended within a range between 0.5 and 5 m

Indicators

Operation indicator (orange)

Excess gain level indicators (ON in green with sensing object in proximity and

ON in orange with no sensing object in proximity)

Fine-tuning indicator (green)

Ambient temperature

Operating

--10

°

C to 55

°

C (14

°

F to 131

°

F) with no icing

Ambient humidity

Operating

35 to 85%

Influence of temperature on sensing distance

(at 23

°

C)

±

10% max. --10

°

C to 55

°

C (14

°

F to 131

°

F)

Insulation resistance

50 M

min. (at 500 VDC) between current carrying parts and case

Dielectric strength

1,000 VAC (50/60 Hz) for 1 min between current carrying parts and case

Vibration resistance

Destruction: 10 to 150 Hz, 1.5-mm double amplitude or 100 m/s

2

(approx. 10G)

for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 300 m/s

2

(approx. 30G) for 3 hours each in X, Y, and Z directions

Degree of protection

IEC IP50 with the sensor cable and protective cover attached

Material

Case

PTB resin

Cover

Polycarbonate

Teaching monitor function

Orange and green indicators shared by operation and excess gain indication

Output status

Normally open or normally closed selectable

Weight (packaged state)

Approx. 75 g (with 2-m cable)

Accessories

Mounting brackets and instruction sheet

Summary of Contents for E2CY

Page 1: ...m E2CY X1R5A E2CY C2A E2CY V3A Part number E2CY T11 J SENSOR HEADS J AMPLIFIER UNIT Specifications J RATINGS CHARACTERISTICS Sensor Heads Part number E2CY X1R5A E2CY C2A E2CY V3A Target object Non fer...

Page 2: ...a max residual voltage of 1 V Self diagnostic output NPN open collector output of 100 mA max with a max residual voltage of 1 V Circuit protection Reverse polarity surge voltage and load short circuit...

Page 3: ...ion mode selector 1 Teaching without sensing object The E2CY is used as a normal proximity sensor T 2 Teaching with or without the sensing object The E2CY is used for detecting the difference in targe...

Page 4: ...he target object so that it passes through the sensing position once Target object passing Sensor Head No switches are operated OFF after the indicators are ON for 1 s Sensor Head side OK In Operation...

Page 5: ...ash repeat from step 1 Or change the Sensor Head position or set the resolution selector to FINE and then repeat from step 1 Sensor Head Sensing level difference TEACH button Sensor Head side ON OK Se...

Page 6: ...and then repeat from step 1 Press the TEACH button after locating the other sensing level in front of the sensing surface Sensor Head Sensing object at a certain position TEACH button Sensor Head side...

Page 7: ...side ON OK Sensor Head side Flashing No good Step 4 Sensitivity setting position Control panel Indicators Excess gain level indicators Set the operation mode selector to RUN Sensor Head ON point The...

Page 8: ...8 x 8 x 1 mm Sensing distance vari able 0 15 to 1 5 mm Y mm E2CY V3A Y mm Target object Aluminum 8 x 8 x 1 mm Sensing distance vari able 0 2 to 2 0 mm Sensitivity adjustment 100 Sensitivity adjustment...

Page 9: ...Stainless steel SUS304 Sensing distance X mm Sensing distance X mm Aluminum brass and copper Target object size d mm E2CY V3A Stainless steel SUS304 Sensing distance X mm J TEMPERATURE INFLUENCE TYPIC...

Page 10: ...3 m E2CY C2A Vinyl insulated round coaxial cable with 2 5 dia 28 0 08 with a single conductor Standard length 3 m E2CY V3A Mounting Holes Vinyl insulated round coaxial cable with 2 5 dia 28 0 08 with...

Page 11: ...utput transistor does not operate in this mode RUN Mode This mode is used for the normal operation of the Sensor Resolution Selector If the E2CY often has a teaching error when detecting fine tuning d...

Page 12: ...ong distance Note 1 All indicators will be ON if the target object is at a position of approximately 80 of the preset sensing distance 2 All indicators will be OFF at a position of approximately 110 o...

Page 13: ...not short circuit the load The load short circuit protection function is triggered provided that power within the rated voltage range is supplied to the E2CY without a mistake in polarity Load Brown S...

Page 14: ...ote A similar problem will occur if ferrous metal such as iron is located close to the E2CY Correctly connect the load to the control output Correctly connect the self diagnostic output line Perform t...

Page 15: ...e following illustration and lift up the fiber insertion part of the Amplifier Unit in the direction shown by arrow 4 so the Amplifier Unit can be removed easily No screwdriver is required to remove t...

Page 16: ...e East Commerce Drive Schaumburg IL 60173 NOTE DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters to inches divide by 25 4 1 800 55 OMRON OMRON CANADA INC 885 Milner Avenue Scarborough Ontario...

Reviews: