E2CY
E2CY
7
Positioning Teaching
Step 1
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Set the operation
mode selector to T.
Press the TEACH
button once with no
target object
located.
Sensor Head
No target object
TEACH button
Sensor
Head side
ON
OK
Step 2
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Press the TEACH
button once after
locating the target
object at the
desired teaching
position.
If all the indicators
flash, repeat from
step 1.
Sensor Head
Target object at a
certain position
TEACH button
Sensor
Head side
Flashing
No good
Sensor
Head side
ON
OK
Step 3
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Press the TEACH
button once with
the target object
located at the same
position.
If all the indicators
flash, repeat from
step 1.
Sensor Head
Target object at a
certain position
TEACH button
Sensor
Head side
ON
OK
Sensor
Head side
Flashing
No good
Step 4
Sensitivity setting
position
Control panel
Indicators
(Excess gain level indicators)
Set the operation
mode selector to
RUN.
Sensor Head
ON point
The ON-point is set at
the teaching position.
Operation mode selector
OFF after the
indicators are
ON for 1 s.
Sensor
Head side
OK
AUTO Mode
This mode is used for adjusting the target distance to its maximum without using any target object.
Set the operation mode selector
to AUTO with no target object
located at the sensing distance
Status of target object
Control panel
Indicators
(Excess gain level indicators)
g
j
located at the sensing distance.
The sensing distance is automatically
set to 80% to 110% of the stable
sensing distance of the E2CY.
Sensor Head
No target object
TEACH button
Sensor
Head side
Flashing
No good
OFF after the
indicators are
ON for 1 s.
Sensor
Head side
OK
Note: If the operation mode selector is set to AUTO when the E2CY is turned ON, the E2CY will make sensitivity adjustments automati-
cally. To maintain the sensitivity after adjustment, be sure to set the operation mode selector to RUN.