76
Setting up a network
Section 3-2
3.
Select the
OK
or
Apply
button at the bottom of the window. The
OK
button
will close the DTM Configuration User Interface.
Note
If, when pressing the
Apply
or
OK
button, no I/O modules have been selected
as yet, a warning message will be displayed. The I/O modules can be
selected later. Pressing the
OK
button with the warning, will apply the
changed device address.
After changing the address in the slave DTM Configuration User Interface, the
updated address will be shown in the Network view, next to the device name.
Changing the DTM
address via the Master
DTM
The slave DTM address can also be changed via the Master DTM. To accom-
plish this, first open the Slave DTM Address Assignment table.
1,2,3...
1.
Select the Master DTM in the Network view.
2.
Right click the mouse, and select the
Additional functions
entry from the
context menu.
3.
Select the
Slave DTM Address Assignment
function.