3
Type the
#4 j=65536
command in the
Power PMAC IDE Terminal.
4
Confirm that Gate3[1].Chan[1].Serial-
EncDataA=65536 or so is displayed.
5
Type the
#5 j=65536
command in the
Power PMAC IDE Terminal.
6
Confirm that Gate3[0].Chan[2].Serial-
EncDataA=65536 or so is displayed.
3-6-5
Verification of the MOTF on the Actual Machine
Confirm that the settings of the MOTF are operating correctly on the actual machine.
1
Type the
&1 start 1
command in the
Power PMAC IDE Terminal.
2
Confirm that the linear motors and Gal-
vo Scanner for the X and Y axes oper-
ate in synchronization.
3 Connection Procedures
3-50
Application Guide Laser Application (O052)