CJ2H-CPU6

@

-EIP

4

Performance Specifications

Items

CJ2H-

CPU64-EIP

CPU65-EIP

CPU66-EIP

CPU67-EIP

CPU68-EIP

User Memory

50K steps

100K steps

150K steps

250K steps

400K steps

I/O Bits

2,560 bits

Processing 
Speed

Overhead Processing Time

Normal Mode: 200 

μ

s

(If tag data links are used with EtherNet/IP, add the following to the above time: 100 

μ

s + Number of transferred 

words 

×

 (0.33 

μ

s or 0.87 

μ

*

))

*

When High-speed interrupt function is used

Execution Time

Basic Instructions: 0.016 

μ

s min.;

Special Instructions: 0.048 

μ

s min.

Interrupts

I/O Interrupts and 
External Interrupts

Start time of interrupt task : 26 

μ

s or 17 

μ

*

 (30 

μ

s in unit Ver.1.0)

Return time to cyclic task : 11 

μ

s or 8 

μ

*

 (15 

μ

s in unit Ver.1.0)

*

When High-speed interrupt function is used 

Scheduled 
Interrupts

Start time of interrupt task : 22 

μ

s or 13 

μ

*

 (27 

μ

s in unit Ver.1.0)

Return time to cyclic task : 11 

μ

s or 8 

μ

*

 (15 

μ

s in unit Ver.1.0)

*

When High-speed interrupt function is used

Maximum Number of Connectable Units

Total per CPU Rack or Expansion Rack: 10 Units max.;
Total per PLC: 40 Units max.

Maximum Number of Expansion Racks

3 max.

CIO Area

I/O Area

2,560 bits (160 words): Words CIO 0000 to CIO 0159

Link Area

3,200 bits (200 words): Words CIO 1000 to CIO 1199

CPU Bus Unit Area

6,400 bits (400 words): Words CIO 1500 to CIO 1899

Special I/O Unit Area

15,360 bits (960 words): Words CIO 2000 to CIO 2959

DeviceNet Area

9,600 bits (600 words): Words CIO 3200 to CIO 3799

Internal I/O Area

3,200 bits (200 words): Words CIO 1300 to CIO 1499
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143
Cannot be used for external I/O.

Work Area

8,192 bits (512 words): Words W000 to W511
Cannot be used for external I/O.

Holding Area

8,192 bits (512 words): Words H000 to H511
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed.
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function 
block instances (i.e., they are allocated only for internal variables in function blocks). 

Auxiliary Area

Read-only: 31,744 bits (1,984 words)

7,168 bits (448 words): Words A0 to A447

24,576 bits (1,536 words): Words A10000 to A11535

Read/write: 16,384 bits (1,024 words) in words A448 to A1471

Temporary Area

16 bits: TR0 to TR15

Timer Area

4,096 timer numbers (T0000 to T4095 (separate from counters))

Counter Area

4,096 counter numbers (C0000 to C4095 (separate from timers))

DM Area

32k words (Bits in the DM Area can be addressed either by bit or by word.) 
DM Area words for Special I/O Units: D20000 to D29599 (100 words 

×

 96 Units)

DM Area words for CPU Bus Units: D30000 to D31599 (100 words 

×

 16 Units)

EM Area

32k words/bank 

×

 25 banks max.: E00_00000 to E18_32767 max.

(Bits in the EM Area can be addressed either by bit or by word.) 

32K words 

×

 4 

banks

32K words 

×

 4 

banks

32K words 

×

 10 

banks

32K words 

×

 15 

banks

32K words 

×

 25 

banks

Force-set/reset 
Enabled Banks

EM3

EM3

EM6 to EM9

EM7 to EME

EM11 to EM18

Force-setting/resetting is enabled only for areas specified for automatic address allocation.

Index Registers

IR0 to IR15
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can 
be set so that they are unique in each task or so that they are shared by all tasks.) 

Cyclic Task Flag Area

128 flags

Memory Card

128 MB, 256 MB, or 512 MB

Operating Modes

PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in 

this mode.

MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to 

present values in I/O memory, are enabled in this mode.

RUN Mode:

Programs are executed. This is the normal operating mode.

Execution Mode

Normal Mode

Programming Languages

Ladder Logic (LD),
Sequential Function Charts (SFC),
Structured Text (ST), and
Instruction Lists (IL)

Function 
Blocks

Maximum number of definitions

2,048

Maximum number of instances

2,048

Tasks

Type of Tasks

Cyclic tasks
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt 
tasks)

Number of Tasks

Cyclic tasks: 128
Interrupt tasks: 256
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic 
tasks is actually 384 max.)

Summary of Contents for CJ2H-CPU68-EIP -

Page 1: ...P as a standard feature for high speed high capacity Ethernet based networking Features High speed high capacity EtherNet IP is built into every model The CIP communications protocol is supported for...

Page 2: ...cessories come with CPU Unit Product name Specifications Current consumption A Model Standards I O capacity Mountable Units Expansion Racks Program capacity Data memory capacity LD instruction executi...

Page 3: ...0 m or less Pollution Degree 2 or less Conforms to JIS B3502 and IEC 61131 2 Noise Immunity 2 kV on power supply line Conforms to IEC 61000 4 4 Overvoltage Category Category II Conforms to JIS B3502 a...

Page 4: ...xiliary Area Read only 31 744 bits 1 984 words 7 168 bits 448 words Words A0 to A447 24 576 bits 1 536 words Words A10000 to A11535 Read write 16 384 bits 1 024 words in words A448 to A1471 Temporary...

Page 5: ...blocks Maximum Size of Symbol 32k words Array Symbols Array Variables One dimensional arrays Number of Array Elements 32 000 elements max Number of Registrable Network Symbols Tags 20 000 max Length...

Page 6: ...00 ms Unit 0 5 ms Can be set for each connection Data will be refreshed at the set interval regardless of the number of nodes Permissible Communications Band 6 000 pps 1 Number of Tag Sets 256 Type of...

Page 7: ...d to enable detecting shorter input pulses Load OFF Function All of the outputs on Basic I O Units can be turned OFF when an error occurs in RUN or MONITOR mode Basic I O Unit Status Monitoring Alarm...

Page 8: ...when operating mode was last changed to RUN mode or MONITOR mode is stored Operation Stop Time Storage The last time a fatal error occurred or the last time the operating mode was changed to PROGRAM...

Page 9: ...ror Detection This function detects an error when the model of a Special I O Unit in the registered I O tables does not agree with the model of Unit that is actually mounted Fatal Error Detection Memo...

Page 10: ...Network Communications Instruction to send required FINS commands to a computer connected via a Host Link Remote Programming and Monitoring Host Link communications can be used for remote programming...

Page 11: ...Programming Console cannot be used with a CJ2H CPU Unit Device Type Setting The unit version does not affect the setting made for the device type on the CX Programmer Select the device type as shown i...

Page 12: ...No protocol or Peripheral Bus Pin No Signal Name Direction 1 FG Protection earth 2 SD TXD Send data Output 3 RD RXD Receive data Input 4 RS RTS Request to send Output 5 CS CTS Clear to send Input 6 5...

Page 13: ...smission Paths Star Baud Rate 100 Mbps 100Base TX Transmission Media Shielded twisted pair STP cable Categories 5 5e Transmission Distance 100 m between hub and node Number of Cascade Connections No r...

Page 14: ...eference Manual Information on communications for CS CJ CP series CPU Units and NSJ series Controllers Describes C mode commands and FINS commands Refer to this manual for a detailed description of co...

Page 15: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Reviews: