Omron CJ2H-CPU68-EIP - Datasheet Download Page 14

CJ2H-CPU6

@

-EIP

14

Related Manuals

Cat. No.

Model

Manual

Application

Description

W472

CJ2H-CPU6

@

-EIP

CJ2H-CPU6

@

CJ-series CJ2 CPU Unit 
Hardware User’s 
Manual

Hardware specifications for CJ2 
CPU Units 

Describes the following for CJ2 CPU Units:

Overview and features

Basic system configuration

Part nomenclature and functions

Mounting and setting procedure

Remedies for errors

Also refer to the 

Software User’s Manual

 (W473).

W473

CJ2H-CPU6

@

-EIP

CJ2H-CPU6

@

CJ-series CJ2 CPU Unit 
Software User’s Manual

Software specifications for CJ2 
CPU Units

Describes the following for CJ2 CPU Units:

CPU Unit operation

Internal memory

Programming

Settings

Functions built into the CPU Unit

Also refer to the 

Hardware User’s Manual

 (W472) 

W474

CJ2H-CPU6

@

-EIP

CJ2H-CPU6

@

CS1G/H-CPU

@@

H

CS1G/H-CPU

@@

-V1

CJ1G/H-CPU

@@

H

CJ1G-CPU

@@

CJ1M-CPU

@@

NSJ

@

-

@@@@

(B)-G5D

NSJ

@

-

@@@@

(B)-M3D

CS/CJ/NSJ-series 
Instructions Reference 
Manual

Information on instructions

Describes each programming instruction in detail.
Also refer to the 

Software User’s Manual

 (W473) when you 

do programming. 

W342

CJ2H-CPU6

@

-EIP

CJ2H-CPU6

@

CS1G/H-CPU

@@

H

CS1G/H-CPU

@@

-V1

CS1D-CPU

@@

H

CS1D-CPU

@@

S

CS1W-SCU

@@

-V1

CS1W-SCB

@@

-V1

CJ1H-CPU

@@

H-R

CJ1G/H-CPU

@@

H

CJ1G-CPU

@@

P

CJ1M-CPU

@@

CJ1G-CPU

@@

CJ1W-SCU

@@

-V1

CP1H-X

@@@@

-

@

CP1H-XA

@@@@

-

@

CP1H-Y

@@@@

-

@

NSJ

@

-

@@@@

(B)-G5D

NSJ

@

-

@@@@

(B)-M3D

CS/CJ/CP/NSJ-series 
Communications 
Command Reference 
Manual

Information on communications 
for CS/CJ/CP-series CPU Units 
and NSJ-series Controllers

Describes C-mode commands and FINS commands
Refer to this manual for a detailed description of commands 
for communications with the CPU Unit using C mode 
commands or FINS commands.

Note:

This manual describes the communications 
commands that are addressed to CPU Units. The 
communications path that is used is not relevant and 
can include any of the following: serial ports on CPU 
Units, communications ports on Serial 
Communications Units/Boards, and Communications 
Units. For communications commands addressed to 
Special I/O Units or CPU Bus Units, refer to the 
operation manual for the related Unit. 

W446

WS02-CX

@@

-V

@

CX-Programmer 
Operation Manual

Support Software for Windows 
computers

CX-Programmer operating 
procedure

Describes operating procedures for the CX-Programmer.
Also refer to the 

Software User’s Manual

 (W473) and 

Instructions Reference Manual

 (W474) when you do 

programming. 

W447

CX-Programmer 
Operation Manual 
Functions Blocks

W469

CX-Programmer 
Operation Manual SFC 
Programming

W464

CXONE-AL

@@

C-V

@

CXONE-AL

@@

D-V

@

CS/CJ/CP/NSJ-series 
CX-Integrator Network 
Configuration Software 
Operation Manual

Network setup and monitoring

Describes the operating procedures for the CX-Integrator.

W463

CXONE-AL

@@

C-V

@

/

AL

@@

D-V

@

CX-One Setup Manual

Installing software from the CX-
One

Provides an overview of the CX-One FA Integrated Tool 
Package and describes the installation procedure. 

Summary of Contents for CJ2H-CPU68-EIP -

Page 1: ...P as a standard feature for high speed high capacity Ethernet based networking Features High speed high capacity EtherNet IP is built into every model The CIP communications protocol is supported for...

Page 2: ...cessories come with CPU Unit Product name Specifications Current consumption A Model Standards I O capacity Mountable Units Expansion Racks Program capacity Data memory capacity LD instruction executi...

Page 3: ...0 m or less Pollution Degree 2 or less Conforms to JIS B3502 and IEC 61131 2 Noise Immunity 2 kV on power supply line Conforms to IEC 61000 4 4 Overvoltage Category Category II Conforms to JIS B3502 a...

Page 4: ...xiliary Area Read only 31 744 bits 1 984 words 7 168 bits 448 words Words A0 to A447 24 576 bits 1 536 words Words A10000 to A11535 Read write 16 384 bits 1 024 words in words A448 to A1471 Temporary...

Page 5: ...blocks Maximum Size of Symbol 32k words Array Symbols Array Variables One dimensional arrays Number of Array Elements 32 000 elements max Number of Registrable Network Symbols Tags 20 000 max Length...

Page 6: ...00 ms Unit 0 5 ms Can be set for each connection Data will be refreshed at the set interval regardless of the number of nodes Permissible Communications Band 6 000 pps 1 Number of Tag Sets 256 Type of...

Page 7: ...d to enable detecting shorter input pulses Load OFF Function All of the outputs on Basic I O Units can be turned OFF when an error occurs in RUN or MONITOR mode Basic I O Unit Status Monitoring Alarm...

Page 8: ...when operating mode was last changed to RUN mode or MONITOR mode is stored Operation Stop Time Storage The last time a fatal error occurred or the last time the operating mode was changed to PROGRAM...

Page 9: ...ror Detection This function detects an error when the model of a Special I O Unit in the registered I O tables does not agree with the model of Unit that is actually mounted Fatal Error Detection Memo...

Page 10: ...Network Communications Instruction to send required FINS commands to a computer connected via a Host Link Remote Programming and Monitoring Host Link communications can be used for remote programming...

Page 11: ...Programming Console cannot be used with a CJ2H CPU Unit Device Type Setting The unit version does not affect the setting made for the device type on the CX Programmer Select the device type as shown i...

Page 12: ...No protocol or Peripheral Bus Pin No Signal Name Direction 1 FG Protection earth 2 SD TXD Send data Output 3 RD RXD Receive data Input 4 RS RTS Request to send Output 5 CS CTS Clear to send Input 6 5...

Page 13: ...smission Paths Star Baud Rate 100 Mbps 100Base TX Transmission Media Shielded twisted pair STP cable Categories 5 5e Transmission Distance 100 m between hub and node Number of Cascade Connections No r...

Page 14: ...eference Manual Information on communications for CS CJ CP series CPU Units and NSJ series Controllers Describes C mode commands and FINS commands Refer to this manual for a detailed description of co...

Page 15: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Reviews: