Comparison between CJ1W-CTL41-E and other Counter
Section D
108
.
Extra Functions
• Programmable Hysteresis
(range [1, 255])
--
• Programmable Hysteresis
(range [1, 255])
• Programmable Output Pulse
(Applies to Digital Outputs)
•
Rate Measurement
(Pulse rate measurement
based on programmable time
window)
• Programmable Digital Inputs
functions to control individual
Counters
Noise Filtering
Counter Inputs
• Counter Inputs A and B:
100 kHz (Fixed)
• Counter Inputs A and B:
10 kHz, 50 kHz, 500 kHz
(Programmable)
• Counter Inputs A and B:
25 kHz, 50 kHz, 250 kHz,
500 kHz (Programmable)
Initial Counter Value
• Can be set in PLC
• The Initial Counter Value is
transferred to the Unit upon
Power-Up/Restart.
• Not supported
• Can be set in PLC
• The Initial Counter Value is
transferred to the Unit upon
Power-Up/Restart.
IORD- and IOWR-
instructions
Run-time configuration:
• DM-configuration data
• Range- and Comparison Data
• (Re) Configure Counter Unit
Run-time operation:
• Read Counter Value
• Error Clear
Not supported
Run-time configuration:
• DM-configuration data
• Range- and Comparison Data
• (Re) Configure Counter Unit
Run-time operation:
• Read Counter Value
• Error Clear
Digital Inputs
--
--
4 Digital Inputs
(24 V, NPN or PNP)
Digital Outputs
--
4 Digital Outputs
(5 to 24 V)
4 Digital Outputs
(12 to 24 V, NPN or PNP)
Interrupts
Interrupt generation to PLC
CPU:
• By Software Outputs
Not supported
Interrupt generation to PLC
CPU:
• By Software Outputs
• Digital Inputs
Error History Log
Function
Storage of up to 30 error records Not supported
Storage of up to 30 error records
CJ1W-CTL41-E
CQM1-CTB41
CS1W-CT041