9
Quick Start Up Reference Guide
Section 1-4
example, if you use an Open Collector encoder (e.g. E6B2-CWZ6C) at 24 V
with 10 m cable, you can typically generate count pulses up to 20 kHz. Therefore,
if you want to generate count pulses with higher frequencies, you should use a
different type of encoder (e.g. E6B2-CWZ1X with Line Driver output or a fast
push-pull 24 V encoder, e.g. E6C2-CWZ5GH) or reduce the length of the
encoder cable.
1-4
Quick Start Up Reference Guide
Operation and
Configuration
Each individual Counter of the Counter Unit can be configured as Circular or
Linear Counter (refer to section the section
1-5 Operating Procedure Guide-
for quick start up information).
The diagram below shows the functions the Unit has available to operate and
configure the Unit (refer to
SECTION 3 Operation and Configuration
).
The
numbers in grey refer to section the table on page 16.
Exchanging data with CPU
The diagram below shows the functions the Unit provides to exchange data
with the CPU (refer to section
SECTION 4 Exchanging Data with CPU
Outputs
Circular
Linear
Counter
1
Hysteresis
5
3
8
2
2
2, 4
2, 4
Capture
Register
Preset
Register
Automatic
Output Control
Counter Inputs
(A, B, Z
Counter
Reset
Counter
Start/Stop
CJ-series CPU Unit
CJ1W-CTL41-E
IOWR
IORD
Interrupts
7
7
8
Unit Output Pattern