![background image](http://html1.mh-extra.com/html/omron/c500-asc04/c500-asc04_operation-manual_743033020.webp)
7
1-4
System Configuration
The ASCII Unit can be mounted to any slot on the CPU Backplane. Before
mounting the ASCII Unit, the DIP switches must be set. Make sure that the pow-
er supply to the PC is turned OFF during installation of the ASCII Unit. A personal
computer used for entering the BASIC program should be connected to Port 1
and other peripheral I/O devices such as a printer or a display terminal can be
connected to Port 2 (refer to the following diagram). For more detailed informa-
tion on peripheral interface connections and timing, refer to
Appendix B.
C500/C1000H/C2000H
CV Series
C120
C500
Expansion
I/O Rack
Plasma Display
Printer
Personal Computer
Bar-code Reader
1-5
Mounting
The ASCII Unit can be mounted to any I/O slot. The control panel must allow
enough space for the connectors, as shown in the figure below.
*1. Height of the ASCII Unit including the base (100
mm)
*2. Height of the ASCII Unit with an RS-232C con-
nector attached (approximately 160 to 180 mm)
Mounting
Section 1-5