97
DIFU(13) 01000
00315
MOV(21)
#0000
DM0100
DIFU(13) 01001
00315
01000
DIFD(14) 01002
01001
00102
MOV(21)
002
*
DM0100
01002
00101
DIFD(14) 01003
00315
INC(38)
DM0100
(PC PUT data)
(ASCII write complete)
00302
(PC PUT data)
Processing after completion of data transfer
Transfer starts
Pointer initialization
Detects ASCII write complete
1 cycle delay
PC READ complete
(at falling edge)
Data storage
P 1
PC WRITE complete
(data storage completion)
Transfer completion
01003
PC Program
Remarks:
After 00315 is ON, store data from the ASCII Unit in sequence from DM 0000
onward.
On PC WRITE completion, the ASCII Unit will be informed that the data has
been stored.
Transfer completion is detected when 00315 is OFF.