3 Check and start operation
3-4 Interpreting beeps and displays
No.
Status
indicator
Power
supply
output
lamp
Battery
mode
lamp
Battery
replace
ment
lamp
Beep
Charging
Description
Solution
15
None
(ON)
AC input voltage is too
low.
Use within the AC input
voltage/frequency range
described in the
specifications.
16
None
(ON)
AC input voltage is too
high and AC input
frequency is too low.
17
None
(ON)
AC input frequency is
too low.
18
None
(ON)
AC input voltage and
AC input frequency are
both too low.
3-4-4 Displays and beeps when there is an equipment
failure
(1) When "Power" switch is "ON"
19
Intermittent
0.5-second
intervals
ON
Discharging
There are too many
connected devices and
the rated capacity is
exceeded. If this state
continues for as long as
or longer than the times
described below,
commercial power
continues to be supplied
through bypass
operation (Note 1)
・
When connection
capacity is at 110% or
higher: Bypass
operation begins
promptly.
Reduce the number of
connected devices until
the display appears as
in status No. 4
20
blinking
bypass
Intermittent
0.5-second
intervals
ON
Discharging
21
OFF
OFF
Battery charge stopped
because the battery
ambient temperature of
40°C or higher was
detected.
Lower the ambient
temperature to less than
40°C.
22
Continuous
---
(Note 2)
Output stopped due to
exceeded connection
capacity.
Turn OFF the power
switches of all devices
connected to the unit
reduce the number of
connected devices, and
turn the “Power” switch
back ON again.
23
Continuous
---
(Note 2)
Check that the
connection capacity has
not exceeded the rated
capacity.
Check that the AC input
of connected devices is
not short-circuited, or
that the connection
capacity does not
exceed the rated
capacity.
BA75T/BA100T/BA100R
48
Summary of Contents for BA100R
Page 23: ...2 Installation and connection 2 1 Installation Incorrect Positions BA75T BA100T BA100R 22...
Page 87: ...8 Note of Chinese 8 Note of Chinese UPS UPS 1 UPS FA OA Windows BA75T BA100T BA100R 86...
Page 88: ...8 Note of Chinese 2 FA OA A VCCI A BA75T BA100T 12 5 BA100R 13 BA75T BA100T BA100R 87 8...
Page 90: ...8 Note of Chinese 5cm AC 25 5 30 4 AC AC AC AC BA75T BA100T BA100R 89 8...
Page 91: ...8 Note of Chinese ON OFF AC INPUT PROTECTION 1mA AC UPS AC UPS BA75T BA100T BA100R 90...
Page 92: ...8 Note of Chinese BA75T BA100T BA100R 91 8...
Page 93: ...8 Note of Chinese AC UPS 25 25 6 40 2 AC AC DC250V BA75T BA100T BA100R 92...
Page 99: ...9 References 9 2 Dimensions Upright stand for BA100R BAP100R BA75T BA100T BA100R 98...
Page 100: ...9 References 9 2 Dimensions Rubber feet BA75T BA100T BA100R 99 9...
Page 101: ...9 References 9 2 Dimensions Using Ear brackets BAP100RS BA75T BA100T BA100R 100...
Page 103: ...9 References 9 4 China RoHS Information 9 4 China RoHS Information BA75T BA100T BA100R 102...