EN
23
Electronic version
Specifications
Table 1.
Parameter
Value
Level measurement range depending
on the version
0…700, 1000, 1500, 2000, 2500,
3000, 4000, 5000, 6000 mm
REF-channel length:
- for sensors of 700, 1000 mm length
- for sensors of 1500 mm length
- for sensors of 2000, 2500 mm length
- for sensors of 3000 mm length
- for sensors of 4000 mm length
- for sensors of 5000 mm length
- for sensors of 6000 mm length
200 mm
700 mm
1000 mm
1500 mm
2000 mm
2500 mm
3000 mm
Limit of the allowed main reduced
error of reduced error of
± 0,5 %*
Interface for measured values output
RS-232, RS-485
Programmable interface transmission
rate
1200, 2400, 4800, 7200, 9600, 14
400, 19 200, 38 400, 57 600,
115 200 bit/sec
Measured value output protocol
(automatic protocol detection)
LLS, Modbus
Power supply voltage (BIS-MX)
8…50 V
Absorbed current, not more than
60 mА
Power consumption, not more than
0,4 W
Body protection rating
IP69K
Electric strength of galvanic insulation,
not less than
5000 V
Ambient temperature
From - 40 to + 80 °C
Extreme temperatures
- 60 and + 85 °C
Summary of Contents for LLS-Ex 5
Page 42: ...РЕДАКЦИЯ 26 10 2021 EDITION ...