OIL-HYDRAULIC PRESSES WITH TWO UPRIGHTS
OPERATION AND MAINTENANCE MANUAL
39
7.10
UNIT FOR HOLDING SLIDE AT T.D.C.
The slide holding device is positioned inside the left upright of the press.
It is made up of the following parts:
1.
Hydraulic cylinder
EMMEBI COP5025 20x1.5 J 65 01 S
2.
Limit switch body
TELEMECANIQUE ZCK-J1
3.
Limit switch head
TELEMECANIQUE ZCK-E67
DANGER:
Check periodically the good working order of the limit switches of the device for holding the
slide at T.D.C. since the malfunctioning of these may present a danger to operator safety.
In particular, when the micro-switch which controls the released slide position is disengaged
from the drive cam, it should not be possible to activate the downstroke of the slide.
7.11
MAINTENANCE OF LUBRICATION SYSTEM
Check regularly the level of grease in the tank of the lubrication unit since the end of this is not indicated by an
electric level indicator.
Moreover the tank should only be filled using the filter provided.
If the above recommendations are not observed, the supplier of the equipment will not be liable for damage and
the guarantee will be declared void.
APPLICATION
QUANTITY
CHANGING
FREQUENCY
LUBRICANT
LUBRICATION
2 Kg
WHEN RUN OUT
ESSO
BEACON - EP1