![OMERA OPI M-400 Operation And Maintenance Manual Download Page 6](http://html1.mh-extra.com/html/omera/opi-m-400/opi-m-400_operation-and-maintenance-manual_3954249006.webp)
OIL-HYDRAULIC PRESSES WITH TWO UPRIGHTS
OPERATION AND MAINTENANCE MANUAL
6
2.1
TEST AND INSPECTION DATA (ACCORDING TO SCHLESINGER STANDARDS)
Drawing
Subject of measurement
Maximum
tolerance mm
Measured data
m m
Flatness of lower face of slide with respect to the
table on the plane of symmetry of the machine.
(The slide can only lean forward)
For machines with up to a maximum pressure of:
Up to 50T.
from 50 to 250 T.
over 250 T.
0,03/300
0,05/300
0,08/300
0,015/300
As above but on the perpendicular plane
For machines with up to a maximum pressure of:
Up to 50T.
from 50 to 250 T.
over 250 T.
0,03/300
0,05/300
0,08/300
0,03/300
Perpendicularity of the direction of slide movement
with respect to the table on the plane of symmetry of
the machine.
For machines with up to a maximum pressure of:
Up to 50T.
from 50 to 250 T.
over 250 T.
0,03/300
0,05/300
0,08/300
0,03/300
As above but on the perpendicular plane
For machines with up to a maximum pressure of:
Up to 50T.
from 50 to 250 T.
over 250 T.
0,03/300
0,05/300
0,08/300
0,018/300