9.5.1.3
Digital Configuration Register
Digital Configuration Register
7
6
5
4
3
2
1
0
Available Assigned/
Channel
Apply
Scaling
Lock
Sensor Range / Type
0
0
?
?
(See Below)
9.5.1.3.1
Sensor Range / Type
Range / Type
Measurement
Type
Units of
Measure
Signals
DIO2
DIO1 **
DIO0
0x00
DIN
0x18
DIN
INPUT 2
INPUT 1
INPUT 0
0x01
RATE
0x19
Hz
RESET
ENABLE
PULSE
0x02
PULSE WIDTH
0x1a
msec
RESET
ENABLE
PULSE
0x03
DUTY CYCLE
0x1b
&
RESET
ENABLE
PULSE
0x04
DELAY
0x1c
msec
RESET
PULSEB
PULSEA
0x05
COUNTER
0x1d
CNT
RESET
ENABLE
PULSE
0x06
U/D COUNTER
0x1e
CNT
RESET
DIR
PULSE
** When configured for Mixed-mode operation (Digital pulse + Process) the DIN1 signal is used for the
Process input signal. The Pulse Delay and Up/Down counter functions are not available.
9.5.1.3.2
Lock
If set, the user-specified units of measure string (4 character maximum) will be used in place of
the default
kg.
9.5.1.3.3
Apply Scaling
If set, the user-defined Offset, and Gain values will be used to adjust the sensor reading:
Result = (Raw Reading * Gain) + Offset
9.5.1.3.4
Assigned
The Assigned bit will always read as 0. Refer to the
Smart Sensor Device Interface
documentation for further information.
9.5.1.3.5
Available
The Available bit will always read as 0. Refer to the
Smart Sensor Device Interface
documentation for further information.