SWITCH #5:
This switch sets the base timing for the RS-6's starter output. The "base
setting" is the total time that the RS-6 engages the starter without regards to "engine running
input" from the Orange/Black Tach Wire or the voltage sensing operation. The base timing
with Switch #1 in the "on" position is 1 second; in the "off" position the starter output base
timing is 1.5 second. If the engine is hard to start, or if more starter output time is needed
otherwise, set Switch #1 to the "off" position.