On the RS-6 module are five switches. These control certain aspects of the system's
operation as follows:
SWITCH #1:
This switch must be set according to the vehicle's engine type: set to the "on"
position for gasoline engines, or set to the "off" position for diesel engines.
SWITCH #2:
This switch sets the predetermined time that the RS-6 allows the engine to
run.
Set to the "on" position, the engine run time is 10 minutes; set to the "off" position, the engine
run time is 20 minutes. Please note that this "run time" is time allowed to expire before the
RS-6 automatically stops the engine; all safety circuits, should one be triggered, will
override the preset run time.
SWITCH #3:
This switch operates an "automatic starting feature". To use this feature, the
control module must be mounted in an accessible location. When this switch is turned "on",
the RS-6 will thereafter automatically start the engine every three hours for the predeter-
mined engine run time. This automatic starting will be repeated five times, unless cancelled
by the ignition switch being turned "on" by the key.
SWITCH #4:
This switch is an "on" or "off" switch; it must be in the "on" position for the
RS-6 to operate.
Programming Switches