Appendix E
iLog Error Messages
Error # Description
Note
-8003
User stopped logging readings.
-10005
Failed to find the iServer.
Ethernet cable is disconnected,
iServer is powered off, connections
across the firewall require longer
“connection to socket time out”
setting.
-10006
Windows socket was closed.
-10007
Windows socket error.
Wrong IP or wrong Port number
was used.
-10008
The iServer failed to respond to a request.
Wrong IP or wrong Port number
was used.
-10011
Response came empty.
No data was sent.
-10012
Device responded with
Possibly the iLog is configured for
"Serial Time Out" string.
wrong product model.
-10014
Terminal Server Mode when the Port is 1000.
Try Port 2000 in iLog configuration.
-15100
Error on obtaining the temperature reading.
Possibly the iLog is configured for
wrong product model.
-15105
Error on obtaining the humidity reading.
Possibly the iLog is configured for
wrong product model.
-15110
Error on obtaining the dew point reading.
Possibly the iLog is configured for
wrong product model.