background image

Omega FP-5070 Series Flow Sensors

3

5.  Calibration

The K-Factors listed here represent the number of pulses the sensor will generate for each measured engineering unit. They are listed 

in U.S. gallons, liters and milliliters (mL) for each sensor model.

Sensor

 

Model

Flow

 

Insert

K-FACTORS

Pulses per

 

U.S. GAL

Pulses per

 

LITER

Pulses per

mL

FP-5072-PV 2 mm

5685

1502

1.502

FP-5074-PV 4 mm

2316

612

0.612

FP-5076-PV NONE

1249

330

0.330

4.2  Instrument Connections

IMPORTANT!

•  K-Factors must be considered as approximate 

values.

•  The number of pulses per volumetric unit may vary 

depending on the medium and the installation.

•  For optimum performance, the system must be 

calibrated after installation.

FLOW

OMEGA

FPM-5500/FPM-9020A

Black

Shield

FLOW

Input

Gnd.

10k Ω

+

5 to 24 

VDC

-

Black  

Shield

Red

•  Pull-up resistor required (10 kΩ recommended).  Consult your instrument manual for 

  additional information.

Other

instrument

External Power supply

Red

Black

Shield

Freq. IN

Sen. Pw

r.

Freq. IN 

Iso. Gnd

Open Collector 

Sensor

Std. Sensor

Red

FLOW 

FP-5072

FP-5072

FP-5072

OMEGA

FP-90 Series

Sensr Gnd

(SHIELD)
Sensr IN

(RED)
Sensr V+

(BLACK)

9
8
7

FLOW

OMEGA

FPM-5500/FPM-9020A

Black

Shield

FLOW

Input

Gnd.

10k Ω

+

5 to 24 

VDC

-

Black  

Shield

Red

•  Pull-up resistor required (10 kΩ recommended).  Consult your instrument manual for 

  additional information.

Other

instrument

External Power supply

Red

Black

Shield

Freq. IN

Sen. Pw

r.

Freq. IN 

Iso. Gnd

Open Collector 

Sensor

Std. Sensor

Red

FLOW 

FP-5072

FP-5072

FP-5072

OMEGA

FP-90 Series

Sensr Gnd

(SHIELD)
Sensr IN

(RED)
Sensr V+

(BLACK)

9
8
7

FLOW

OMEGA

FPM-5500/FPM-9020A

Black

Shield

FLOW

Input

Gnd.

10k Ω

+

5 to 24 

VDC

-

Black  

Shield

Red

•  Pull-up resistor required (10 kΩ recommended).  Consult your instrument manual for 

  additional information.

Other

instrument

External Power supply

Red

Black

Shield

Freq. IN

Sen. Pw

r.

Freq. IN 

Iso. Gnd

Open Collector 

Sensor

Std. Sensor

Red

FLOW 

FP-5072

FP-5072

FP-5072

OMEGA

FP-90 Series

Sensr Gnd

(SHIELD)
Sensr IN

(RED)
Sensr V+

(BLACK)

9
8
7

Upper body

Lower Body,

3-2507.080-4x

(x = size of flow insert)

(Example: Lower Body with 2 mm insert = 3-2507.080-42)

FLOW

Flow inserts:

2 mm: #3-2507.081-2

3 mm: #3-2507.081-3

4 mm: #3-2507.081-4

Rotor,

#3-2507.080-2

Quad ring seal,

#3-2507.080-3

Cable plug,

#3-2507.080-5

6.  Replacement Parts

Summary of Contents for FP-5070 Series

Page 1: ...e mail info omega com For latest product manuals www omegamanual info FP 5070 SERIES Flow Sensors Shop online at omega comSM User sGuide...

Page 2: ...pecifications without notice Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Servi...

Page 3: ...ft cable Pipe fitting adapter G 1 4 x 1 4 in NPT 2 included G 1 4 in port threads Upper body with electronic switch Lower body with built in rotor psi bar 6 9 100 5 5 80 4 1 60 2 8 40 1 4 20 0 40 40...

Page 4: ...ews required customer supplied 32 5 mm 1 28 in bolt circle 4 Wiring Details 4 1 Cable Extensions The standard 25 foot sensor cable can be extended to 300 m 1000 ft using 2 conductor shielded twisted p...

Page 5: ...supply Red Black Shield Freq IN Sen Pwr Freq IN Iso Gnd Open Collector Sensor Std Sensor FP 5072 FP 5072 FLOW FLOW Input Gnd 10k 5 to 24 VDC Black Shield Red Pull up resistor required 10 k recommended...

Page 6: ...pen or pencil body to adjust flow insert depth 7 Install rotor quad ring and upper body Hand tighten only Do not overtighten upper body or the lower body assembly tabs will break 8 Reprogram instrume...

Page 7: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 8: ...city Indicators M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simula...

Reviews: