Omega FP-5070 Series Flow Sensors

1

2.  Specifications

General

Flow Range:

•  -2V sensor:..........400 to 2800 mL/m (0.105 to 0.740 U.S. gpm)

•  -4V sensor:..........1300 to 6000 mL/m (0.343 to 1.585 U.S. gpm)

•  -6V sensor:..........3200 to 12000 mL/m (0.845 to 3.170 U.S. gpm)

Linearity: .................±0.25% of full range

Repeatability: ..........±0.25% of full range

Viscosity range: ......0.2 to 20.0 centistokes

Pipe connections: ...G 

1

/

4

 in. ports, 

1

/

4

 in. NPT (male) pipe adapters 

(2 included)

Cable length: ..........Std: 7.6m (25 ft), max.: 300 m (1000 ft)

Cable type: .............2-conductor shielded, twisted-pair, 22 AWG

Shipping Weight: ....0.4 kg (0.8 lb)

1.  Description

The FP-5070 Series Mini Flow Sensors contain a free-running 

rotor which is driven by the fluid flow. Within the given 

measurement range, the rotational speed of the rotor is 

proportional to the fluid flow rate. Permanent magnets built into 

the rotor actuate an electronic switch in the top of the sensor 

generating a square-wave output signal proportional to flow rate. 

Both opaque and transparent fluids can be measured from 0.2 to 

20.0 centistokes.

Wetted sensor parts are constructed of PVDF and FPM, making 

the sensor suitable for use with most process fluids, including most 

acids, bases, light oils, and solvents.

OMEGA FP-5070 Series Flow Sensors

FLOW 

Cable plug 

25 ft cable

Pipe fitting adapter 

1

/

4

 x 

1

/

4

 in. NPT 

(2 included) 

1

/

4

 in.  

port threads 

Upper body with 
electronic switch

Lower body with 

built-in rotor

psi

bar
6.9 100

5.5 80

4.1 60

2.8 40

1.4 20

0

-40
-40

0

-18

40

4

80
27

120

49

160

71

200

93

240
116

280
138

°F

°C

0

20

40

60

70

80

0.25

0.50

0.75

1.00

1.25

1.50

3.63

7.25

10.88

14.50

18.13

21.76

PSI BAR

Flow rate (%) of full scale

Pressure Drop Across Sensor vs. Flow Rate

-2V

-3V

-4V

-6V

WARNING!

WARNING

!

SAFETY INSTRUCTIONS

1.  Do not remove from pressurized lines.

2.  Do not exceed maximum temperature/pressure specifications.

3.  Pipe fitting must be installed by certified welder only.

4.  Do not install/service without following installation instructions (see sensor manual).

5.  Wear safety goggles and face shield during installation/service.

6.  Do not alter product construction.

7.  Failure to follow safety instructions could result in severe personal injury!

Polar organic solvents (e.g., ketones and chlorinated 

hydrocarbons) and aromatic hydrocarbons are not 

compatible with this sensor.

Standards and Approvals

• 

CE

• 

Manufactured under ISO 9001

Wetted Materials

• Housing: ......................PVDF

•  Flow insert:..................PTFE

•  Quad ring seal:............FPM

• Rotor: ..........................PVDF

•  Pipe thread adapters:..PVDF

•  Suitable for clean fluids only

Electrical

Power: ........................... 5 to 24 VDC ±10%, regulated, 

10 mA max. 

Output Type: .................. Open-collector, sinking, 10 mA max.

Max. Temperature/Pressure Rating

•  5.5 bar @  -30 °C (80 psi @ -22 °F)

•  5.5 bar @   24 °C (80 psi @ 75 °F)

•     3 bar @ 120 °C (45 psi @ 248 °F)

Summary of Contents for FP-5070 Series

Page 1: ...e mail info omega com For latest product manuals www omegamanual info FP 5070 SERIES Flow Sensors Shop online at omega comSM User sGuide...

Page 2: ...pecifications without notice Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Servi...

Page 3: ...ft cable Pipe fitting adapter G 1 4 x 1 4 in NPT 2 included G 1 4 in port threads Upper body with electronic switch Lower body with built in rotor psi bar 6 9 100 5 5 80 4 1 60 2 8 40 1 4 20 0 40 40...

Page 4: ...ews required customer supplied 32 5 mm 1 28 in bolt circle 4 Wiring Details 4 1 Cable Extensions The standard 25 foot sensor cable can be extended to 300 m 1000 ft using 2 conductor shielded twisted p...

Page 5: ...supply Red Black Shield Freq IN Sen Pwr Freq IN Iso Gnd Open Collector Sensor Std Sensor FP 5072 FP 5072 FLOW FLOW Input Gnd 10k 5 to 24 VDC Black Shield Red Pull up resistor required 10 k recommended...

Page 6: ...pen or pencil body to adjust flow insert depth 7 Install rotor quad ring and upper body Hand tighten only Do not overtighten upper body or the lower body assembly tabs will break 8 Reprogram instrume...

Page 7: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 8: ...city Indicators M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simula...

Reviews: