![background image](http://html1.mh-extra.com/html/omega/cn8200-series/cn8200-series_user-manual_737605023.webp)
37
CN8200
Ordering Codes
Ordering Number
Description
CN8201
1/16 DIN Single output
CN8202
1/16 DIN Dual output
Output Type - Ordering Suffix
First Output Second Output
Relay
-R1
-R2
dc Pulse
-DC1
-DC2
1A SSR
-T1
-T2
4-20 mA (500 ohm max.)
-F1
-F2
4-20 mA (1000 ohm max.)
-FH1
-FH2
Optional Power Supply
24 Vac/Vdc
-LV
Additional Options (cannot be field-installed)
Description
Ordering Suffix
Single alarm relay
-AL1
Dual alarms, ac SSR
-AL2
Dual alarms, DC 24V
-AL3
RS-232 communications
-C2
RS-485 communications
-C4
RS-485 w/Digital input, switch closed
-C4-DIC
RS-485 w/Digital input, switch open
-C4-DIO
RS-485 w/Digital input, 5V
-C4-DIV
RS-485 communications, MODBUS
-C4-MOD
RS-485 MODBUS w/Digital input, switch closed
-C4-MOD-DIC
RS-485 MODBUS w/Digital input, switch open
-C4-MOD-DIO
RS-485 MODBUS w/Digital input, 5V
-C4-MOD-DIV
Process output, 4 to 20 mA
-PVSV1
Process output, 0 to 5 Vdc
-PVSV2
Digital input, switch closed w/1 alarm
-RSP1
Digital input, switch open w/1 alarm
-RSP2
Digital input, 5V w/1 alarm
-RSP3
Transducer power supply, 15 Vdc
-XP1
Transducer power supply, 12 Vdc
-XP2
Transducer power supply, 10 Vdc
-XP3
Transducer power supply, 5 Vdc
-XP4
36
Technical
Specifications
Input Type
Thermocouple
B, C, E, J, K, N, NIC, NNM, R, S, T, Platinel II
Maximum lead resistance 100 ohms
for rated accuracy
RTD
Platinum 2- and 3-wire, 100 ohms at
0° C, DIN curve standard (0.00385)
1000 ohms available
Linear
0-50 mV/10-50 mV, 0-5 V/1-5 V
0-20 mA/4-20 mA, 0-100 mV, 0-10 V
Output Device
R
5 A (120/240 Vac) relay, normally
open, used for switching resistive loads.
If an “R” output is selected, order
CNQUENCHARC. If relays or solenoids
are to be driven, select the “T” output.
DC
20 Vdc pulsed output for solid-state relays.
T
1 A @ 120/240 Vac , solid-state relay, zero
voltage-switched and optically isolated from
drive signal. Only resistive loads to 1A may
be controlled directly. Larger loads may be
controlled using an external contactor.
F
4-20 mA, full output to load with 500 ohm
impedance max.
FH
High impedance 4-20 mA (1000 ohms max.)