Carbon Monoxide Alarm 

CI 200

Operating Manual 

11/2018 en  

v1.0

Summary of Contents for CI 200

Page 1: ...Carbon Monoxide Alarm CI 200 Operating Manual 11 2018 en v1 0...

Page 2: ...ons 7 Important Information on Preventive Measures 10 Notes on Use 10 Operating Elements 11 Interconnecting the CO alarms without an alarm system 12 Setting Up With an Alarm System 13 Registering CO a...

Page 3: ...20 End of Service Life 21 CO Alarm Function Test 21 What You Also Need to Know 22 Symptoms Following Carbon Monoxide Poisoning 22 Reaction Times of the CO Alarm 24 Technical Data 25 Guarantee 26 Infor...

Page 4: ...ed Clear the source of the danger where this is immediately obvious and you do not put your own life at risk You and others at risk must move away from the danger area Inform the fire service and wait...

Page 5: ...ered the CO alarm sends a radio signal which can be received by alarm systems in the Protect and ProHome series or other CO alarms The alarm system and or other CO alarms then also issue an alarm A co...

Page 6: ...eck the contents of the package carefully If anything is missing or has been damaged during transport DO NOT put the smoke detector into operation 1 CO alarm CI 200 Assembly material screws dowels 2 b...

Page 7: ...Depending on the concentration level carbon monoxide can have fatal effects within minutes Warning Carbon monoxide is a highly flammable invisi ble odourless gas Take every alarm seriously Avoid prod...

Page 8: ...mmediately Caution Risk of property damage through the use of inappropriate batteries The use of inappropriate batteries can cause a loss of function of the device Only use batter ies of the type desc...

Page 9: ...sons the sensors must not be operated in excess of ten years As result of chemical wear of the sensor the CO alarm does not work properly after the service life of ten years specified Replace the devi...

Page 10: ...un on gas as well as air supplies and exhausts serviced at regular intervals by specialists Notes on Use The CO alarms can be used individually or when connected to each other Alternatively the CO ala...

Page 11: ...ents 1 4 5 8 7 6 2 3 1 Alarm signal LED red 5 Battery compartment cover 2 Fault signal LED yellow 6 Assembly fittings 3 Operating signal LED green 7 Battery compartment 4 Button for connection muting...

Page 12: ...test the product close to your ears Use appropriate ear protectors when connecting the CO alarms 1 Insert two appropriate batteries in the battery compartment of all the CO alarms provided Pay attent...

Page 13: ...ting the CO alarms 1 Select the Register menu option on the alarm system 2 Insert two appropriate batteries in the battery compartment of one of the CO alarms master device Pay attention that the batt...

Page 14: ...fication of alarms when a CO alarm is triggered If you have linked the CO alarms to each other without an alarm system notification occurs accordingly without an alarm system The secondary devices sla...

Page 15: ...information below at the height at which most people breath also applies for rooms without a heating appliance Although carbon monoxide has a similar density to the ambient air it is normally expelle...

Page 16: ...because fresh air flowing in could cause a delay in alarms being triggered in the direct vicinity of a cooking area in closed containers or concealed areas in the vicinity of extractor fans in wet or...

Page 17: ...the CO alarm concerned within 30 days 1 Remove the CO alarm from its fitting 2 Change the batteries observe correct polarity 3 Replace the CO alarm on the fitting When the CO alarm is connected to an...

Page 18: ...errors In case of doubt contact a specialist 1 Ensure that there are no electric cables gas or water pipes near the installation location 2 Drill two holes about 30 mm apart at the intended installat...

Page 19: ...2 flashes accordingly Check the function of the CO alarm or change the CO alarm Alarm mode If the CO alarm detects a critical concentration of carbon monoxide it issues an alarm The CO alarm issues f...

Page 20: ...y alarm seriously Follow the instructions provided in Section In the Event of an Alarm on Page 14 Low Battery Charge Warning The CO alarm automatically detects and signals a low battery charge In this...

Page 21: ...ete a function test of the CO alarm at regular intervals at least once a month 1 Press the button 4 for about 1 second The CO alarm issues four short acoustic signals interrupted by a pause of 5 secon...

Page 22: ...ase of unborn children infants pregnant women senior citizens and people with heart or respiratory problems Concentration Exposure and Symptoms 30 ppm Maximum permissible concentration to which one ma...

Page 23: ...3200 ppm Severe headache dizziness and nausea within 5 to 10 minutes fatal within 25 to 30 minutes 6400 ppm Severe headache dizziness and nausea within 1 to 2 minutes fatal within 10 to 15 minutes 12...

Page 24: ...ording to the levels of carbon monoxide Concentration Time Until CO Alarm is Triggered Up to 50 ppm Approx 2 hours Up to 100 ppm Approx 1 to 1 5 hours Up to 300 ppm Approx 10 to 40 minutes From 300 pp...

Page 25: ...ns L x W x H 90 mm x 90 mm x 29 mm Frequency radio 868 MHz Alarm volume 85 dB A Batteries 2xalkaline AA 1 5V Recommended GoldPeakGP15A RaymaxLR6 Standard EN 50291 1 2010 A1 2012 Ambient conditions 0 C...

Page 26: ...product is available at http productip com f 83849 or scan the QR Code Guarantee The period of guarantee is 24 months The period of guarantee begins on the date of purchase It is essential to keep th...

Page 27: ...sposed of in normal domestic waste and that they must be brought to collection points provided by local public waste authorities Packaging materials must be disposed of according to local regulations...

Page 28: ...Subject to change without prior notice Carbon Monoxide CO Alarm CI 200 v1 0 11 2018 Art Nr Art No 6121...