2-3-18
When maintenance item U411 (Automatic adjustment in the scanner) is run using the specified original (P/N
AVGR23234P
)
the following adjustments are automatically made:
Adjusting the scanner magnification (U065)
Adjusting the scanner leading edge registration (U066)
Adjusting the scanner center line (U067)
When maintenance item U411 (Automatic adjustment in the DP) is run using the specified original (P/N
AVGR23235K
)
the following adjustments are automatically made:
* : When running this test chart, you first must clean the feed rollers with alcohol and ensure the DP width guides
are correctly positioned against the original.
Adjusting the DP magnification (U070)
Adjusting the DP leading edge registration (U071)
Adjusting the DP center line (U072)
Image quality
Item
Specifications
100% magnification
Print: ±0.8%
Copy: ±1.5%
Using DP: ±2.0%
Enlargement/reduction
Copy: ±2.0%
Using DP: ±2.5%
Lateral squareness
Copy: ±2.0mm/200mm
Using DP: ±2.5mm/200mm
Leading edge registration
Print: 1.5 mm or less
Copy: 2.5mm or less
Using DP: 2.5mm or less
Skewed paper feed
(left-right difference)
Print: 1mm /100mm or less
Copy: 1mm /100mm or less
Using DP: 1.5mm /100mm or less
Lateral image shifting
Print: 2.0 mm or less
Copy: 3.0mm or less
Using DP: 3.0mm or less
Service Manual
Y116
540-5
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...