![Olivetti d-Copia 4003MF Service Manual Download Page 415](http://html1.mh-extra.com/html/olivetti/d-copia-4003mf/d-copia-4003mf_service-manual_3940000415.webp)
2-2-19
*1: 50/60 ppm model only
YC4
1
LFANN
-
0/24 V DC
LFM: On/Off
Connected to
the LSU fan
motor
2
+24V0_E3
O
24 V DC
24 V DC power output
YC7
1
+3.3V2_E2
O
3.3 V DC
3.3 V DC power output
Connected to
the waste
toner sesor
2
WTLEDN
I
0/3.3 V DC
WTS(LED): On/Off
3
WTSENS
I
Analog
WTS output signal
4
+3.3V2_E2
O
3.3 V DC
3.3 V DC power output
YC8
1
+3.3V1_E1
O
-
3.3 V DC power output
Connected to
the MP paper
sesor
2
GND
-
-
Ground
3
MPFSENS
I
0/3.3 V DC
MPS: On/Off
YC9 *1
1
3.3V2_E2
O
3.3 V DC
3.3 V DC power output
Connected to
the duplex
sesor 1
2
GND
-
-
Ground
3
DUJAMSEN1
N
I
0/3.3 V DC
DUS: On/Off
YC10 *1
1
REARSWN
I
0/3.3 V DC
RECSW: On/Off
Connected to
the right
cover switch
2
GND
-
-
Ground
YC11 *1
1
ENVMOT
O
0/5 V DC
ENVM: On/Off
Connected to
the envelope
motor
2
GND
-
-
Ground
YC12
1
OUTB3
O
0/3.3 V DC
EM B3 drive control signal
Connected to
the eject
motor
2
OUTB1
O
0/3.3 V DC
EM B1 drive control signal
3
OUTA3
O
0/3.3 V DC
EM A3 drive control signal
4
OUTA1
O
0/3.3 V DC
EM A1 drive control signal
YC13 *1
1
FACEUDRN
O
0/24 V DC
FUSOL: On/Off
Connected to
the faceup
solenoid
2
+24V2_E2
O
24 V DC
24 V DC power output
3
FACEDDRN
O
0/24 V DC
FUSOL: On/Off
Connector
Pin
Signal
I/O
Voltage
Description
Service Manual
Y116
540-5
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...