2PV/2PW-1
1-5-29
(2) Detaching and refitting the power source PWB
Procedure
1. Remove the right rear cover, right cover
and right lower cover (see page 1-5-6).
2. Remove four screws and then remove
the power source shield.
Screws A and B are unidentical, there-
fore, do not mix up.
Figure 1-5-41
3. Remove all connectors from power
source PWB.
4. Remove two screws.
5. Release three hooks and then remove
the power source PWB.
6. Check or replace the power source
PWB and refit all the removed parts.
Figure 1-5-42
Power source shield
Screw B
Screws A
Screw A
Power source PWB
Screw
Hook
Hook
YC103 YC105
YC104
YC101
YC102
Hook
Screw
Service Manual
Y116650-5
Summary of Contents for d-Color MF2613En
Page 1: ...SERVICE MANUAL Multifuction Digital Copier d Color MF2613En d Color MF2614En Code Y116650 5...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 38: ...2PV 2PW 1 2 14 This page is intentionally left blank Service Manual Y116650 5...
Page 136: ...2PV 2PW 1 3 98 This page is intentionally left blank Service Manual Y116650 5...
Page 190: ...2PV 2PW 1 4 54 This page is intentionally left blank Service Manual Y116650 5...
Page 241: ...2PV 2PW 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit Service Manual Y116650 5...
Page 284: ...2PV 2PW 1 5 94 This page is intentionally left blank Service Manual Y116650 5...
Page 288: ...Service Manual Y116650 5 This page is intentionally left blank...
Page 328: ...2PV 2PW 2 2 10 This page is intentionally left blank Service Manual Y116650 5...
Page 354: ...2PV 2PW 2 3 26 This page is intentionally left blank Service Manual Y116650 5...
Page 375: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 07 2014 1ST EDITION 375 Y116650 5...