2PV/2PW
1-4-21
5304
Broken cleaning lamp Y
wire
When the cleaning lamp Y is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum unit Y and Drum relay PWB (YC5)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
lamp Y.
Replace the drum unit Y. (see page 1-5-21).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
6000
Broken fuser heater wire
The detected temperature of
fuser thermistor does not rise
1
C/1.8
F after the fuser
heater has been turned on
continuously for 10 s in warm-
ing up.
The fuser temperature does
not reach 100
C/212
F after
the fuser heater has been
turned on continuously for
30 s in warming up.
The detected temperature of
fuser thermistor does not
reach the specified tempera-
ture (ready indication temper-
ature) after the fuser heater
has been turned on continu-
ously for 60 s in warming up.
The detected temperature of
fuser thermistor does not rise
1
C/1.8
F after the fuser
heater has been turned on
continuously for 10 s during
printing.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser heater and power source PWB
(YC102)
Fuser unit and eject PWB (YC3)
Eject PWB (YC1) and engine PWB (YC19)
Deformed connec-
tor pin.
See page 1-4-22.
Defective triac.
See page 1-4-22.
Fuser thermostat
triggered.
Reinsert the fuser unit (see page 1-5-26).
Broken fuser
heater wire.
Replace the fuser unit (see page 1-5-26).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
6020
Abnormally high fuser
thermistor temperature
The fuser thermistor detects a
temperature higher than
240
C/464
F.
By the activation of the high
temperature error detection
circuit (230
C/446
F or more)
of fuser thermistor, the illumi-
nation of fuser heater was
forcibly turned off and 10 s
has elapsed.
Deformed connec-
tor pin.
See page 1-4-22.
Defective triac.
See page 1-4-22.
Shorted fuser
thermistor.
Replace the fuser unit (see page 1-5-26).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
Code
Contents
Causes
Check procedures/
corrective measures
Service Manual
Y116650-5
Summary of Contents for d-Color MF2613En
Page 1: ...SERVICE MANUAL Multifuction Digital Copier d Color MF2613En d Color MF2614En Code Y116650 5...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 38: ...2PV 2PW 1 2 14 This page is intentionally left blank Service Manual Y116650 5...
Page 136: ...2PV 2PW 1 3 98 This page is intentionally left blank Service Manual Y116650 5...
Page 190: ...2PV 2PW 1 4 54 This page is intentionally left blank Service Manual Y116650 5...
Page 241: ...2PV 2PW 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit Service Manual Y116650 5...
Page 284: ...2PV 2PW 1 5 94 This page is intentionally left blank Service Manual Y116650 5...
Page 288: ...Service Manual Y116650 5 This page is intentionally left blank...
Page 328: ...2PV 2PW 2 2 10 This page is intentionally left blank Service Manual Y116650 5...
Page 354: ...2PV 2PW 2 3 26 This page is intentionally left blank Service Manual Y116650 5...
Page 375: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 07 2014 1ST EDITION 375 Y116650 5...