2PV/2PW
1-4-14
2200
Drum motor error
The drum motor ready input is
not given for 5 s during the
drum motor is ON.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum motor and engine PWB (YC13)
Defective drive
transmission sys-
tem of the drum
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective drum
motor.
Replace the drum motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
2330
Fuser pressure release
motor error
When the fuser pressure
release motor is driven, the
motor over-current detection
signal is detected continu-
ously for 8 times (800 ms) at
100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser pressure release motor and engine
PWB (YC38)
Defective drive
transmission sys-
tem of the fuser
pressure release
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective fuser
pressure release
motor.
Replace the fuser pressure release motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
2340
Fuser pressure release
motor time-out error
When the fuser pressure
release motor is driven, the
envelope switch (EVSW) is
not detectable for 6 s.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser pressure release motor and engine
PWB (YC38)
Defective drive
transmission sys-
tem of the fuser
pressure release
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective fuser
pressure release
motor.
Replace the fuser pressure release motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
Code
Contents
Causes
Check procedures/
corrective measures
Service Manual
Y116650-5
Summary of Contents for d-Color MF2613En
Page 1: ...SERVICE MANUAL Multifuction Digital Copier d Color MF2613En d Color MF2614En Code Y116650 5...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 38: ...2PV 2PW 1 2 14 This page is intentionally left blank Service Manual Y116650 5...
Page 136: ...2PV 2PW 1 3 98 This page is intentionally left blank Service Manual Y116650 5...
Page 190: ...2PV 2PW 1 4 54 This page is intentionally left blank Service Manual Y116650 5...
Page 241: ...2PV 2PW 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit Service Manual Y116650 5...
Page 284: ...2PV 2PW 1 5 94 This page is intentionally left blank Service Manual Y116650 5...
Page 288: ...Service Manual Y116650 5 This page is intentionally left blank...
Page 328: ...2PV 2PW 2 2 10 This page is intentionally left blank Service Manual Y116650 5...
Page 354: ...2PV 2PW 2 3 26 This page is intentionally left blank Service Manual Y116650 5...
Page 375: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 07 2014 1ST EDITION 375 Y116650 5...